Document toolboxDocument toolbox

Determine the Mod State of SA380TX-L

The SA380TX-L data logger has, to date, undergone four major product revisions, indicated by the products "mod state"

Mod State

Comment

Mod State

Comment

1

Original SA380TX-L

2

RS485 Hardware Fix

3

Addition of Ethernet Card

4

Incorporation of a 3G modem

5

Incorporation of a 4G modem

Determining Mod State

The Mod State is indicated by the first numerical digit of the serial number. For instance serial number:

LAS-3.0-MPE-05010

indicates a Mod-State 3 device.

There are two OEMs used in manufacture designated by “TIO” and “MPE”.

Serial Number Ranges:

 

TIO

MPE

Mod State 1, Mode State 2, Mod State 3

N/A

Below 8000

Mod State 4

below 51718

Below 10639

Mod State 5

51718 onwards

10639 Onwards

SA380TX-L firmware remains backwards compatible with all device Mod States. The primary difference is the type of cellular connectivity.