Firmware Status

Suitable for SA380 Mod State 2+

LEGACY

New Features:


None

Bug Fixes:


Incoming Data Call Behaviour

It has been noted that the SA380 and SA380TX data-loggers can attempt to answer "phantom incoming data calls" when no inbound call exists.

This firmware release adds the following behaviour:

  • Where 3G and above modems are installed, inbound data calls will never be answered, as the modems do not support them. The "CSD" configuration setting has no effect.
  • Where 2G modems are installed, the decision to answer an apparent inbound data call is governed by the "CSD" parameter in the advanced XML configuration settings:

<bearer type="gprs" apn="internet" user="" pass="" csd="0" gsmDisable="0" roaming="1" gsm2G="1" />
 
csd="1" : Inbound calls will be answered
csd="0" : Inbound calls will be rejected


The setting is not available on the graphical WebCfg interface, or the device touch-screen.