SA380TX Network Access
SA380TX Network Access
Three methods of access are provided:
- Direct cable connection for local access using a laptop
- Internet / intranet
- Dial-up
Direct cable connection
- Connect the logger to a computer using a crossed RJ45 network cable. If a crossed network cable is not available, two 'normal' RJ45 cables and a hub can be used
- Wait approximately 60 seconds for the logger to assign an IP address to your computer.
- Start Internet Explorer on the computer and enter the logger’s IP address
(eg http://10.0.1.1:80/)
DHCP Server
The SA380TX can act as a DHCP allocator (to allow direct cable connections). From firmware revision 1211 onward, this behaviour can be prevented in the logger's XML configuration by setting <dhcp>0</dhcp> in the ConfigEth section, or by selecting a connection profile whose bearer type is "ethernet".
The SA380TX is factory-set with a fixed IP address of 10.0.1.1:80. This address can be changed – see the 'How to change the IP address' section in Local Access.
Internet / intranet
If the logger is connected to a company network, its IP address will have been set when the unit was commissioned.
To access the logger, type the address into your browser eg. http://138.60.225.10
, multiple selections available,
Related content
SA380TX Applications
SA380TX Applications
Read with this
Make a Point-to-Point Ethernet Connection to a SA380TX
Make a Point-to-Point Ethernet Connection to a SA380TX
More like this
SA380TX Web Configuration
SA380TX Web Configuration
Read with this
SA380TX Troubleshooting Direct Cable Connections
SA380TX Troubleshooting Direct Cable Connections
More like this
SA380TX Release Notes
SA380TX Release Notes
Read with this
SA380TX MS1/2 Master with SA380 Slave
SA380TX MS1/2 Master with SA380 Slave
More like this