Document toolboxDocument toolbox

Manual configuration of peak pressure threshold for hydraulic clamp-lock points

User story

As aRCM Flight Engineer
I want toConfigure a peak pressure threshold for points traces for the middle region of the trace
So thatI can receive alarm only on the region that provides the indication of degradation

Visualisation

Release

This guide was produced based on the Centrix R58 release.

Guide

Open the Alerts tab in Centrix.

Click the Create Alert dropdown in the bottom left of the screen, and select Points.

Select the Site for the asset you want to create the alarm for and fill in the remaining General Settings using the guidance below;

FieldDescriptionExample / recommendation
SiteThe site that contains the asset you want to configure the alarm forN/A
Alert NameThis is the primary name for the alert that will be displayed on the alert listing and in any e-mailse.g. 8003 Points Pressure (Movement)
E-mailThe list of e-mail addresses that should receive any alertsLeave blank unless you don't use Labels, or want this alarm only for yourself
SubscribedWhether e-mails should be sent or notChecked
Suppression PeriodThe period of time for which repeat alarms should be suppressed (not e-mailed)10-60 minutes would be a sensible default
PriorityPriority of alarm, displayed on the alert listing and in the e-mail subject & bodyCan be used depending on importance of asset, or when configuring multiple threshold levels (e.g. low/med/high)
LabelsThe labels to apply to the alert, will determine who receives e-mails for the alertsSet-up a collection of labels for the groups of people that should receive certain alarms, then set them accordingly on the alarm

 

Select the Capture for the asset you want to configure the threshold for.

Under Thresholds, click Add.

  • Leave Direction as (– Any –) unless you want to configure different thresholds for N-R and R-N directions.
  • Select Pressure Movement (Shared) as the Episode. This is a globally shared episode that represents the middle (movement) region of a pressure trace.
  • Enter your desired value for the Max Upper threshold (e.g. 90)
  • Click Save



Click OK to save the alarm.

 

Warning - Consistency checking

The effectiveness of using the shared (global) episode is dependent on the consistency between the shared episode and the specific asset you are configuring the alarm for. In some cases this may be so inconsistent that no alarms would ever fire.

Please read Validating the use of a shared (global) episode for an asset for further instruction.