Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 6 Current »

Three methods of access are provided:

  • Direct cable connection for local access using a laptop
  • Internet / intranet
  • Dial-up

Direct cable connection

  • Connect the logger to a computer using a crossed RJ45 network cable.  If a crossed network cable is not available, two 'normal' RJ45 cables and a hub can be used
  • Wait approximately 60 seconds for the logger to assign an IP address to your computer.
  • Start Internet Explorer on the computer and enter the logger’s IP address
    (eg http://10.0.1.1:80/)

DHCP Server

The SA380TX can act as a DHCP allocator (to allow direct cable connections). From firmware revision 1211 onward, this behaviour can be prevented in the logger's XML configuration by setting <dhcp>0</dhcp> in the ConfigEth section, or by selecting a connection profile whose bearer type is "ethernet". 

The SA380TX is factory-set with a fixed IP address of 10.0.1.1:80.  This address can be changed – see the 'How to change the IP address' section in Local Access.

Note that:

The web server is on port 8080.


Internet / intranet

If the logger is connected to a company network, its IP address will have been set when the unit was commissioned.

To access the logger, type the address into your browser eg. http://138.60.225.10