  • Start Internet Explorer on the computer and enter the logger’s IP address
    (eg http://10.0.1.1:80/)
Note
titleDHCP Server

The SA380TX can act as a DHCP allocator (to allow direct cable connections). From firmware revision 1211 onward, this behaviour can be prevented in the logger's XML configuration by setting <dhcp>0</dhcp> in the ConfigEth section, or by selecting a connection profile whose bearer type is "ethernet". 

The SA380TX is factory-set with a fixed IP address of 10.0.1.1:80.  This address can be changed – see the 'How to change the IP address' section in Local Access.

...

...

Note that:

The web server is on port 8080.

Internet / intranet

If the logger is connected to a company network, its IP address will have been set when the unit was commissioned.

To access the logger, type the address into your browser eg. http://138.60.225.10