The SA380TX data logger has, to date, undergone four major product revisions, indicated by the products "mod state"

Mod State

Comment

1

Original SA380TX

2

Reliability enhancements to the original design

3

New higher-powered CPU and updated operating system

4

Incorporation of a 3G modem

5

Incorporation of a 4G modem

Determining Mod State

The Mod State is indicated by the first numerical digit of the serial number. A Mod State 3 device is shown below:

Example serial numbers of all 4 mod states are shown here:

Serial Number Ranges:


Mod State 1 & Mod State 2

Serial Number below 08230 

Mod State 3

Serial Number 8230 onward

Mod State 5

Serial Number 12635 onwards


The higher CPU power of Mod State 3+ devices and the greater data-throughput of Mod State 4 and 5 devices enables the SA380TX to run more advanced firmware that supports programmable mathematical operations, and large master / slave networks.

Because of this,  SA380TX firmware is divided into two camps:


Mod State 1 & 2 Firmware

This firmware is essentially frozen at revision 1.5T446. To provide continued support for the product, minor releases may be made from time-to-time to rectify bugs found in existing firmware, or to extend the life of the product.


Mod State 3+ Firmware

This firmware is actively developed and contains all the latest features and functionality. For a comprehensive overview of the latest features, see the SA380TX Release Notes.


Modem Technology

Type

Start Serial Number

Up to

2G

1

8865

MIx 2G..3G

8866

9011

3G

9012

12321

4G

12950