The current state of the SA-SSI data logging unit, including information about the it's current connection status, events and battery can be found on the status page.
To navigate to this press the "Status" button on the home page:
This will display the following page:
The indicators on the right of the page, display the current state of each application function. Further information on the meaning of each of these can be found in the following table.
Application Function | Black | Red | Amber | Green |
---|---|---|---|---|
Internet | N/A | Not connected | N/A | Connected |
SSI | USB adapter not connected | No connection/communication with Park Module | Incorrect ident | OK |
Power | N/A | Running on battery/battery voltage low | Running on batter/battery voltage ok | Mains connected |
OS | N/A | Not started | Miss configured | OK |
Centrix | N/A | Not connected | No traffic for more than 1 minute | OK/Connected |
Events | Uninitialised | Internal fault | Miss configured | OK |
NTP | N/A | Not connected | Clock not set | OK |
Watchdog | N/A | An application has failed | N/A | All OK |
Internet connection and IP address
Further information regarding the IP address of the SA-SSI can be viewed by pressing on the "Internet" button, as shown below:
Navigating to the IP Addresses page will display all the IP addresses associated with the data logger, as shown below: