S-LX System Specifications
Electrical |
|
---|---|
Serial Input (Non-Intrusive) | 1 x RS232 Full-Duplex 3-Wire Input - 57.6 kbps Max. |
Multipurpose Serial Input (Intrusive) | 2 x RS232/422/485 Software Selectable 921.6 kbps Max. |
Ethernet | 2 x 10/100 Mbps MDIX - RJ45 |
USB | 1 x USB 2.0 Host - Type A Connector |
Cellular | LTE (4G) Modem with 3G fall-back |
Supply Voltage | 85 V to 250 V AC |
Power Consumption | 5 W Typical, 10 W Max |
Wire Gauge for Power Supply Inputs. | 2.5 mm sq. Max. |
Further detailed specifications for S-LX compute & HZS PSU/Isolation module can be found below.
General Arrangement Drawings
S-LX Module Specification
Electrical |
|
---|---|
CPU | ARM7 Cortex A8 1 GHz |
RAM | 512 MB DDR3 DRAM |
OS | Debian Industrial Linux |
Ethernet | 2 x 10/100 Mbps MDIX - RJ45 |
Serial | 2 x RS232/422/485 Software Selectable 921.6 kbps Max. |
USB* | 1 x USB 2.0 Host - Type A Connector |
Cellular | LTE (4G) Modem with 3G fall-back |
SIM | Standard Mini SIM |
Storage | 8 GB eMMC onboard 1 GB Industrial SD Card |
Input Voltage | 12 V to 24 V DC |
Power Consumption | 5.4 W Max |
Isolation | > 4 MΩ at 1,000 V DC |
Indications | Power, Storage, Connectivity, USB, Run, Fault, Signal Strength |
*Where USB hubs are utilised, these hubs must also be Network Rail Type Approved for Monitoring Applications.
Mechanical | |
---|---|
Length | 129 mm |
Width | 27 mm |
Depth | 101 mm |
Weight | 230 g |
Mounting | DIN Rail |
Environmental Ratings |
|
---|---|
IP Rating | 2X |
IK Rating | 06 |
Temperature Range | -5 to +55 °C |
Flammability | UL94-V0 |
Environmental | EN 50125-3 |
EMC | EN 50121-4 |
HZS Module Specification
Electrical |
|
---|---|
Serial Input | 1 x RS232 Full-Duplex 3-Wire Input |
Serial Output | 2 x RS485 Half-Duplex 2-Wire Output |
Baud Rate | 57,600 bps max. |
Input Impedance | > 1 MΩ on both RS232 TX and RX Lines |
Power Supply | 85 V to 250 V AC |
Power Consumption | 0.6 W (HZS Module Only) |
Output Voltage | 12 V DC +/- 5% |
Maximum Output Load | 9 W |
Isolation | > 4 MΩ at 1,000 V DC |
Indications | Power, TX Active, RX Active |
Mechanical | |
---|---|
Length | 129 mm |
Width | 27 mm |
Depth | 101 mm |
Weight | 370 g |
Mounting | DIN Rail |
Environmental Ratings |
|
---|---|
IP Rating | 3X |
IK Rating | 06 |
Temperature Range | -5 to +55 °C |
Flammability | UL94-V0 |
Environmental | EN 50125-3 |
EMC | EN 50121-4 |
Creepage & Clearance | EN 50124-1 |
Electrical Safety | EN 61010-1 |
Network Rail Data Logging | NR/L2/SIG/30036 |
Orderable Parts
Part No: | Description | Photo |
---|---|---|
SLX-VHLC-SS | S-LX Assembly for single module Vaughn Harmon Level 1 x HZS, 1 x SLX, DIN Mount | |
SLX-VHLC-DS | S-LX Assembly for twin module Vaughn Harmon Level 2 x HZS, 1 x SLX, DIN Mount | |
SLX-TT-SS | S-LX Assembly for SSI Tech's Terminal system. 1 x HZS, 1 x SLX, DIN Mount | |
SLX-SEAR-SS | S-LX Assembly for SEAR II Level Crossing 1 x HZS, 1 x SLX, DIN Mount | |
SLX-SDL-SS | S-LX Assembly for SSI Data Links. Park Signalling Equipment Not Included. 1 x HZS, 1 x SLX, DIN Mount | |
SLX-S2-SS | S-LX Assembly for S2 TDM systems. 1 x HZS, 1 x SLX, DIN Mount | |
SLX-MCS-XSS | S-LX Assembly for MCS system ACE 1 x RS422 Isolator, 1 x HZS, 1 x SLX, DIN Mount | |
SLX-HXP3-SS | S-LX Assembly for HXP-3 Track Circuit Systems. 1 x HZS, 1 x SLX, DIN Mount | |
SLX-FUES-SS | S-LX Assembly for FUES Hot Axle Box Detector 1 x HZS, 1 x SLX, DIN Mount | |
SLX-FLEX-0S | S-LX Assembly for Flex Life Level Crossing. 1 x SLX, DIN Mount | |
SLX-AZLM-SS | S-LX Assembly for AzLM Axle Counter ACE with Parallel Card Interface. See application notes. 1 x HZS, 1 x SLX, 19” Rack Mount | |
SLX-AZLM-SD | Air-Gapped S-LX Assembly for AzLM Axle Counter ACE with Serial Card Interface. See application notes. 1 x HZS, 2 x SLX, 19” Rack Mount | |
SLX-1024-DD | S-LX Assembly for 1024 TDM systems. 2 x HZS, 2 x SLX, DIN Mount |
Spares & Accessories
Part No: | Description | Photo |
---|---|---|
MIS-WHP-06 | 2/3/4G Hi-Gain Mag-Mount Antenna with 6m Cable | |
MIS-WHP-10 | 2/3/4G Hi-Gain Mag-Mount Antenna with 10m Cable | |
MIS-WHP-15 | 2/3/4G Hi-Gain Mag-Mount Antenna with 15m Cable | |
MIS-BRK-RACK | 19” Rack, 1U Mounting Tray, fits S-LX , suitable for other applications | |
MIS-BRK-DIN | Stainless Steel BR930 Size DIN Rail Bracket, fits S-LX, suitable for other applications | |
SLX-0-DB9-X | DB-9 RS232 Cable - 'X' = Length in metres | |
SLX-0-DB25-X | DB-25 RS232 Cable - 'X' = Length in metres | |
SLX-0-SPLIT | DB-9 Three-Way Splitter Cable | |
SLX-0-GB | Replacement S-LX compute module | |
SLX-0-HZS | Replacement HZS PSU / Port Isolators | |
SLX-0-KIT | Replacement plug-coupler kit. Contains all plug couplers |