AzLM Axle Counter systems may be monitored by direct Ethernet or USB connection as shown below:
1 x S-LX may monitor 2 x Axle Counter Evaluators. (ACE) over Ethernet
1 x S-LX may monitor 1 x Axle Counter Evaluators. (ACE) over USB.
Additional ACE may be monitored through the provision of an Ethernet hub, allowed a single antenna to be used.
Connection of the S-LX system is via a monitoring port. The AzLM system may remain in service during installation.
Security is assured by only connecting to 1 of duplicated CPU devices found in each ACE. (2oo2 safety system)
When connected over USB, do not make the USB connection to the same CPU that is connected to the Interlocking.
Appropriate cables shall be provided by the customer
No additional configuration files are required prior to installation.
Sample Overlay Diagram