The "Reed FDM" VTi21 variant is related to the "Reed Relay" firmware, however the FDM monitor supports a different and larger list of frequencies. The VTi21 can be used to monitor the in-band electrical current amplitude of the following frequencies:

ChannelFrequency
F04
F16
F17
F19
F20
F26
F27
F36
F38
F39
F47
F48
F83
F84
F92
803.25 Hz
702.50 Hz
697.50 Hz
687.00 Hz
682.50 Hz
611.75 Hz
607.75 Hz
505.00 Hz
493.50 Hz
488.00 Hz
419.75 Hz
410.25 Hz
446.00 Hz
533.75 Hz
842.00 Hz


  • The VTi21 implements fifteen very narrow-band filters, to determine the amplitude of the current at these frequencies, with a 2.5 Hz bandwidth.
  • The effect is an output signal that is illustrative of the logical state of that channel/frequency. All out-of band noise is rejected. Any deviation in frequency or level in the received signal will result in a drop in the output amplitude.
  • The system may be fitted on both transmitter and receiver. As both systems exhibit the same current range.
  • The output rate of the system is 3 samples per second on each channel.

SA380TX Configuration

4-20mA Output:

The Reed FDM monitor outputs the total current in the frequency range over the 4-20mA interface, however on its own this output is of limited use. 

RS485:

For information on the wiring required for RS485 communications please see VTi21 Hardware Wiring for RS485 Operation  and follow the instructions titled "Wiring for RS485 Operation" or "Alternate Wiring for RS485 Operation" dependant on the SA380TX's hardware configuration.

To configure the VTi21 over RS485, please follow the instructions under the heading "Configuration on RS485" in the VTi21 Configuration guide.

After configuring the RS485 connection, each reported channel needs to be assigned to an analogue channel as per the example shown below.

Installation

The conductor(s) carrying the signals to be monitored must pass through the current transducer connected to the "CH1" input on the VTi21. In this application "CH2" is redundant. The conductors can pass through the current transducer in either direction. 

Reed VTi21 Outputs

The Reed VTi21 sensor can output the following quantities when monitoring Reed receivers.

VTi21-Reed

Slave Channel

VTi21 Input Channel

Quantity

Description

Typical Range

Units

Suggested AoC

11CH 1 FrequencySimple Frequency Measurement (zero crossings)0 to 5000Hz1
21CH 1 Total Current

Total current measured in the reed relay frequency range

0 to 5AmA50
31CH 1 - spectrogram / gain

Capture waveform showing the magnitude spectrum of the input signal. Use a "Triggered Capture" to acquire the Spectrogram. note: includes only measured frequencies as reported on the other channels.




4
CH1 Current at F04Current measured in-band at 803.25 Hz0 to 5AmA50
5
CH1 Current at F16Current measured in-band at 702.50 Hz0 to 5AmA50
6
CH1 Current at F17Current measured in-band at 697.50 Hz0 to 5AmA50
7
CH1 Current at F19Current measured in-band at 687.00 Hz0 to 5AmA50
8
CH1 Current at F20Current measured in-band at 682.50 Hz0 to 5AmA50
9
CH1 Current at F26Current measured in-band at 611.75 Hz0 to 5AmA50
10
CH1 Current at F27Current measured in-band at 607.75 Hz0 to 5AmA50
11
CH1 Current at F36Current measured in-band at 505.00 Hz0 to 5AmA50
12
CH1 Current at F38Current measured in-band at 493.50 Hz0 to 5AmA50
13
CH1 Current at F39

Current measured in-band at 488.00 Hz

0 to 5AmA50
14
CH1 Current at F47Current measured in-band at 419.75 Hz0 to 5AmA50
15
CH1 Current at F48Current measured in-band at 410.25 Hz0 to 5AmA50

16


CH1 Current at F83Current measured in-band at 446.00 Hz0 to 5AmA50
17
CH1 Current at F84Current measured in-band a 533.75 Hz0 to 5AmA50
18
CH1 Current at F92Current measured in-band at 842 Hz0 to 5AmA50