There are a number of pre-configured alert templates available in the system;
Type | Description | Status |
---|
Train Over Speed | Set a minimum transition time between 2 track circuits to detect a speeding train | |
---|
Possible SPAD | Detect when a signal is passed at danger | |
---|
SA380 Slave Offline | Detect when an SA380 slave unit has gone inactive | |
---|
Digital State Change | Detect a state change on any digital input channel | |
---|
Track Flick | Detect a flick on a track circuit by specifying a minimum occupation time | |
---|
Points Flick | Detect loss of detection on a set of points | |
---|
Signal Reversion | Detect a signal reverting to danger when approaching track circuit is occupied | Status |
---|
| |
---|
colour | Yellow |
---|
title | Experimental |
---|
|
|
---|
Analogue Level | Detect when an analogue channel exceeds a given threshold value | |
---|
Capture Trace Levels | Detect when a capture trace exceeds any given threshold values | |
---|
Logger Contact (Comms) Alert | Detect when a dialled logger hasn't been successfully contacted for a given period of time | |
---|