Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


Firmware

Status

Suitable for TX Mod State:
MS1 + MS2MS3+

Status
titleLEGACY

  •   
  •   

1.5T446-3G-A


New Features:

...

None

Bug Fixes:

...

Incoming Data Call Behaviour

It has been noted that the SA380 and SA380TX data-loggers can attempt to answer "phantom incoming data calls" when no inbound call exists.

This firmware release adds the following behaviour:

  • Where 3G and above modems are installed, inbound data calls will never be answered, as the modems do not support them. The "CSD" configuration setting has no effect.
  • Where 2G modems are installed, the decision to answer an apparent inbound data call is governed by the "CSD" parameter in the advanced XML configuration settings:
Code Block
languagexml
<bearer type="gprs" apn="internet" user="" pass="" csd="0" gsmDisable="0" roaming="1" gsm2G="1" />

csd="1" : Inbound calls will be answered
csd="0" : Inbound calls will be rejected


The setting is not available on the graphical WebCfg interface, or the device touch-screen.

1.5T467-611

  • modstate 3 unit can be manufactured with empty SD card, no internal disk flag file is needed.

...

In XML editor tab, user can set:

<RDAQcfg>
  <enabled>1</enabled>
  <targetHost>centrix.org</targetHost>
  <targetPort>7777</targetPort>
 </RDAQcfg>

Any changes in this configuration makes the logger to restart for the configuration to take effect.

...