Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Important general considerations

 

Great care must be taken when adding datalogging to railway signalling systems.

...

Measurement type

Current clamp

Rating

No of turns

DC track circuits

Rowe Hankins NIC361-6A

600mA DC

1

AC track circuits

Northern Design XD-I420-1

5A AC

5MPEC VTi21

1A to 100A AC

1

Points motor current

LEM PointSenz PCM20P

20A DC

1

...

  • Rail temperature
  • Rail vibration
  • Points load pin
  • Clamp lock power pack monitoring
  • Points position monitoring

...

Warning
Note

 Special care must be taken when attaching sensors to rails, pointwork, point machines or anything electrically connected to them.

...

Sensor requirements:

  • Each sensor must have electrical isolation between the 4-20mA output and the trackwork to a minimum of 4M Ohms at 250V.
  • 250mA fuses must be provided in each leg of the current loop.
  • Only Network Rail approved points load pins may be used.
  • When monitoring the pressure in clamp lock power packs, only pressure sensors approved by the manufacturer of the power pack must be used.
  • Where sensors are attached to both rails, a risk assessment must be carried out to ensure that there is no risk of a track circuit being false fed

...