Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Made a note about AOC threshold for tracks monitoring

...

  1. Setup analogue input channel: set channel name and input sensor
  2. Setup data acquisition type

GUI

Setting up analogue input channel

First of all you have to set an appropriate name and input sensor for the analogue channel.

...

Select the appropriate sensor and press the "OK" button to select it for the analogue channel.

Image RemovedImage Added If you are happy with the analogue channel settings, press Save: Image RemovedImage Added

The logger will notify you about the configuration changes:

...

The actual input value can be read on the graph. (Which is -5A now, since we don't have actual sensor connected to the analogue channel.)

Setting up analogue data acquisition

  then enter password and enter: 

...

The next selector dialog shows which analogue channels are collecting acquire-on-change measurements:

 select  

select 701 WI channel: Image Removed

Image Added

Brings you to the acquire-on-change configuration dialog:

 Most  

Most importants settings are the ON/OFF and the "Push to seriverserver" toggle buttons.

For the most basic measurement it is usually enough to enable the acquisition, so just toggle ON/OFF and push to servera typical configuration, set the acquire-on-change threshold to 1% (lower than the default 5%), then toggle push to server and ON/OFF, then save the changes:

Image RemovedImage Added

Now the data collection method is set for the particular analogue channel. Let's see the collected data:

...

Navigate to acquire-on-change historical data for analogue channel 701 WI:

  Image RemovedImage Added 

Image RemovedImage Added

Info
Notice that setting the acquire-on-change configuration will make the logger to acquire a first sample as a base value without any actual input change.

Web interface

Visiting the web interface we will focus on the Analogue Inputs part of the configuration.

Image Added

Let's set AN-A02 to a track circuit and enable acquire-on-change on it:

Set name:

Image Added

Set sensor:

Image Added

Set acquire-on-change:

Image Added

Send to logger:

Image Added WebCFG tool sends and retrieves the configuration again:Image Added

Check the output of the data acquisition:

Image Added Gets to: Image Added

Select today's date:

Image Added

Open acqchg folder:

Image Added

Open the new file for AB TR we just set up:

Image Added

The opened file must contain at least one sample as base acquisition.

Related articles

Filter by label (Content by label)
showLabelsfalse
max5
spacesSSD
showSpacefalse
sortmodified
showSpacefalse
reversetrue
typepage
cqllabel = "kb-how-to-article" and type = "page" and space = "SSD"
labelskb-how-to-article

Page Properties
hiddentrue


Related issues 


...