Comment: Updated HVI channels to indicate the non-useful ones

...

4-20mA Sensor Tables

...

Part No.

...

Variant Description

...

Quantity

...

Quantity Description

...

Value @ 4mA

...

Value @ 20mA

...

Units

...

Suggested AoC

...

4-20mA Sensor Tables

Part No.

Variant Description

Quantity

Quantity Description

Value @ 4mA

Value @ 20mA

Units

Suggested AoC

VTI21-VT1AC Vane Relay VariantTorqueInstantaneous Torque Exerted on the relay vane.0+25m.Nm0.2 m.Nm
VTI21-HVIHVI Receiver VariantAverage CurrentAverage HVI Pulsed Current seen by the VTI21 from input channel 1.0
1500
600mA
5mA
15 mA
VTI21-TI21-TXTI21 / EbiTrack 200 Variant (TX)Average CurrentAverage of upper and lower sideband current from VTI21 input channel 1.05A0
1500
.05 A
VTI21-TI21-TXTI21 / EbiTrack 200 Variant (RX)Average CurrentAverage of upper and lower sideband current from VTI21 input channel 1.0200mA
5
2 mA
VTI21-FS25FS2500 Receiver VariantCenter CurrentAmplitude of the FS2500 center frequency current from VTI21 input channel 1.01500mA5 mA
VTI21-FS26FS2600 Receiver VariantCenter CurrentAmplitude of the FS2500 center frequency current from VTI21 input channel 1.01500mA5 mA
VTI21-ACS
-001
General Purpose AC sensing up to
1.5A
25A RMSCurrentRMS current from VTI21 input channel 1.0
2500
25
mA25 mA
A0.2 A
VTI21-
ACS-020General Purpose AC sensing up to 20A RMS
UM71UM71 VariantCurrent
RMS current from VTI21 input
Current at selected center frequency from VTi21 input channel 1.0
20
5000µA
0.2 A
100µA
VTI21-
UM71
ASTER
UM71
Aster VariantCurrentCurrent at selected center
frequency
frequency from VTi21 input channel 1.05000µA100µA
VTI21-
Reed
REEDReed Relay VariantCurrentCurrent measured across the Reed relay frequency range on input channel 1.05000mA
100mA

...

25mA
VTI21-

...

RFDMReed Relay FDM variantn/anone



RS485 Sensor Tables

VTI21-VT1

Slave Channel

Quantity

Description

Typical Range

Units

Suggested AoC

1TorqueInstantaneous torque exerted on the relay vane-25 to +25m.Nm0.2 m.Nm
2PhasePhase angle between local coil and control coil currents0 to 180Degrees2 degrees
3Local CurrentRMS current in the local coil0 to 500mA5 mA
4Control CurrentRMS current in the track coil0 to 1000mA5 mA
5ChatterDegree of chatter0 to 100%5 %

VTI21-TI21 / VTI21-FS25 / VTI21-FS26

Slave Channel

VTI21 Input Channel

Quantity

Description

Typical Range

Units

Suggested AoC

1






1

Center FrequencyThe Center frequency, in hertz, of the track circuit.388.8 to 508.8Hz1 Hz
2
1
Center frequency CurrentTotal RMS current at the target center frequency0 to 1000mA5 mA
3
1
Lower Side Band currentTotal RMS current at the target lower side band frequency0 to 1000mA5 mA
4
1
Upper Side Band currentTotal RMS current at the target upper side band frequency0 to 1000mA5 mA
5
1
In Band CurrentTotal RMS current seen by the transducer between 300 to 600 Hz0 to 1000mA5 mA
6
1

Spectrogram

or Gain

Capture waveform showing the magnitude spectrum of the input signal. Use a "Triggered Capture" to acquire the Spectrogram.

When spectrum data is not being acquired, this channel shows the current amplifier gain setting

4.8 to 1228.8HzNA
7
1
Loudest FrequencyThe strongest frequency, in hertz, observed in the incoming waveform.4.8 to 1228.8Hz1 Hz
8
1
Total CurrentTotal RMS current seen by the transducer.0 to 1000mA5 mA
9





2

Center FrequencyThe Center frequency, in hertz, of the track circuit.388.8 to 508.8Hz1 Hz
10
2
Center frequency CurrentTotal RMS current at the target center frequency0 to 1000mA5 mA
11
2
Lower Side Band currentTotal RMS current at the target lower side band frequency0 to 1000mA5 mA
12
2
Upper Side Band currentTotal RMS current at the target upper side band frequency0 to 1000mA5 mA
13
2
In Band CurrentTotal RMS current seen by the transducer between 300 to 600 Hz0 to 1000mA5 mA
14
2

Spectrogram

or Gain

Capture waveform showing the magnitude spectrum of the input signal. Use a "Triggered Capture" to acquire the Spectrogram.

When spectrum data is not being acquired, this channel shows the current amplifier gain setting

4.8 to 1228.8HzNA
15
2
Loudest FrequencyThe strongest frequency, in hertz, observed in the incoming waveform.4.8 to 1228.8Hz1 Hz
16
2
Total CurrentTotal RMS current seen by the transducer.0 to 1000mA5 mA

VTI21-HVI

Slave Channel

VTI21 Input Channel

Quantity

Description

Typical Range

Units

Suggested AoC

1 - ANA





1

Average Current


HVI FrequencyThe
average RMS current of the positive and negative portion of the HVI pulse signal0 to 1000mA5 mA21Positive PeakPeak magnitude of the positive portion of the HVI pulse signal0 to 10000 to 1000
frequency of pulses0 to 5Hz0.1 Hz
2 - ANAHVI CurrentRMS Current of the pulsed waveform0 to 1500mA5 mA
3 - ANA
1Negative PeakPeak magnitude of the negative portion of the HVI pulse signal
Noise CurrentThe RMS current observed between pulses.0 to 1500mA5 mA
4 - DIG
1FrequencyFrequency of the HVI pulse train0 to 5Hz0.1 Hz51Total CurrentTotal RMS current seen by the VTI21 receiver0 to 1000mA5 mA62Average CurrentThe average RMS current of the positive and negative portion of the HVI pulse signal0 to 1000mA5 mA72Positive PeakPeak magnitude of the positive portion of the HVI pulse signal0 to 1000mA5 mA82Negative PeakPeak magnitude of the negative portion of the HVI pulse signal0 to 1000mA5 mA92FrequencyFrequency of the HVI pulse trainTotal
Pulse ConflictSet TRUE if pulses are observed to be bleeding through from adjacent track sectionsDigitalN/AOn Change
5 - ANARejection RateProportion of pulses deemed not to be genuine HVI pulses0 to 100%Don't push to server - for diagnostic use by Mpec only
6 - ANARejection ReasonBitfield encoding the reason a pulse was not accepted.8 bitsN/A
7- ANASensitivityThreshold used to identify pulse events0 to 2621440N/A
8 - ANAPulse WaveformIf this channel is requested as a capture, the VTi21 will return a high-resolution waveform of the last observed pulse0 to 1500mATriggered Capture
9 - ANA






2

HVI FrequencyThe frequency of pulses0 to 5Hz0.1 Hz
10 - ANA
2
HVI Current
Total
RMS
current seen by the transducer.
Current of the pulsed waveform0 to
1000
1500mA5 mA

...

11 -

...

Slave Channel

VTI21 Input Channel

Quantity

Description

Typical Range

Units

Suggested AoC

11CH 1 CurrentRMS current observed on Channel 10 to 2500
ANANoise CurrentThe RMS current observed between pulses.0 to 1500mA5 mA
22CH 2 CurrentRMS current observed on Channel 20 to 2500mA5 mA3NADerived CurrentRMS current derived for an unmonitored 3rd phase in a balanced three-phase system.0 to 2500mA5 mA4NACH1 Leads CH2Digital Output - TRUE if the waveform on CH1 is observed to lead that of CH2TRUE or FALSENANA5NACH1 Lags CH2Digital Output - TRUE if the waveform on CH1 is observed to lag that of CH2TRUE or FALSENANA

...

12 - DIGPulse ConflictSet TRUE if pulses are observed to be bleeding through from adjacent track sectionsDigitalN/AOn Change
13 - ANARejection RateProportion of pulses deemed not to be genuine HVI pulses0 to 100%Don't push to server - for diagnostic use by Mpec only
14 - ANARejection ReasonBitfield encoding the reason a pulse was not accepted.8 bitsN/A
15 - ANASensitivityThreshold used to identify pulse events0 to 2621440N/A
16 - ANAPulse WaveformIf this channel is requested as a capture, the VTi21 will return a high-resolution waveform of the last observed pulse0 to 1500mATriggered Capture


VTI21-ACS

Slave Channel

VTI21 Input Channel

Quantity

Description

Typical Range

Units

Suggested AoC

1

1

CH 1 CurrentRMS current observed on Channel 1 (output at 100 Hz, low pass filtered with cutoff of 9 Hz)0 to
20
25A0.2 A
2
2
CH
2
1 Average CurrentAverage RMS current observed on Channel
2
1, over one second period.0 to
20
25A0.2 A
3
NA
2
Derived
CH 2 Current

RMS current

derived for an unmonitored 3rd phase in a balanced three-phase system.

observed on Channel 2 (output at 100 Hz, low pass filtered with cutoff of 9 Hz)

0 to
20

Slave Channel

VTI21 Input Channel

Quantity

Description

Typical
25A0.2 A
4
NACH1 Leads CH2Digital Output - TRUE if the waveform on CH1 is observed to lead that of CH2TRUE or FALSENANA5NACH1 Lags CH2Digital Output - TRUE if the waveform on CH1 is observed to lag that of CH2TRUE or FALSENANA

...

CH 2 Average CurrentAverage RMS current observed on Channel 2, over one second period.0 to 25A0.2 A

VTI21-UM71

Slave Channel

VTI21 Input Channel

Quantity

Description

Typical Range

Units

Suggested AoC

1








1

CH 1 FrequencyChannel 1 Frequency Selected1700 to 2600Hz1
2
1
CH 1 Side Band RatioRatio of lower to upper frequency (0%=all lower, 100%=all upper)0 to 100%%5
3
1
CH 1 Raw FrequencySimple Frequency Measurement (zero crossings)1600 to 2700Hz100
4
1
CH 1 Total CurrentTotal current in the UM71 band0 to 5mAµA100
5
1
CH 1 current 1700HzCurrent measured at 1700Hz0 to 5mAµA100
6
1
CH 1 current 2000HzCurrent measured at 2000Hz0 to 5mAµA100
7
1
CH 1 current 2300HzCurrent measured at 2300Hz0 to 5mAµA100
8
1
CH 1 current 2600HzCurrent measured at 2600Hz0 to 5mAµA100
9
1

CH 1 Spectrogram or Gain

Capture waveform showing the magnitude spectrum of the input signal. Use a "Triggered Capture" to acquire the Spectrogram.

1 to 32
1
10








2

CH 2 FrequencyChannel 1 Frequency Selected1700 to 2600Hz1
11
2
CH 2 Side Band RatioRatio of lower to upper frequency (0%=all lower, 100%=all upper)0 to 100%%5
12
2
CH 2 Raw FrequencySimple Frequency Measurement (zero crossings)1600 to 2700Hz100
13
2
CH 2 Total CurrentTotal current in the UM71 band0 to 5mAµA100
14
2
CH 2 current 1700HzCurrent measured at 1700Hz0 to 5mAµA100
15
2
CH 2 current 2000HzCurrent measured at 2000Hz0 to 5mAµA100
16
2
CH 2 current 2300HzCurrent measured at 2300Hz0 to 5mAµA100
17
2
CH 2 current 2600HzCurrent measured at 2600Hz0 to 5mAµA100
18
2

CH 2 Spectrogram or Gain

Capture waveform showing the magnitude spectrum of the input signal. Use a "Triggered Capture" to acquire the Spectrogram.

1 to 32
1

VTI21-Reed

Slave Channel

VTI21 Input Channel

Quantity

Description

Typical Range

Units

Suggested AoC

1










1

CH 1 FrequencySimple Frequency Measurement (zero crossings)0 to 5000Hz1
2
1
CH 1 Total CurrentTotal current measured in the reed relay frequency range
0 to 5A
0 to 5000mA
50
10
3
1

CH 1 - channel 211

Total Current at 363Hz

0 to 5A
0 to 5000mA
50
10
4
1

CH 1 - channel 212

Total Current at 366Hz

0 to 5A
0 to 5000mA
50
10
5
1

CH 1 - channel 213

Total Current at 369Hz

0 to 5A
0 to 5000mA
50
10
6
1

CH 1 - channel 214

Total Current at 372Hz

0 to 5A
0 to 5000mA
50
10
7
1

CH 1 - channel 215

Total Current at 375Hz

0 to 5A
0 to 5000mA
50
10
8
1

CH 1 - channel 216

Total Current at 378Hz

0 to 5A
0 to 5000mA
50
10
9
1

CH 1 - channel 217

Total Current at 381Hz

0 to 5A
0 to 5000mA
50
10
10
1

CH 1 - channel 218

Total Current at 384Hz

0 to 5A
0 to 5000mA
50
10
11
1
CH 1 - spectrogram / gain

Capture waveform showing the magnitude spectrum of the input signal. Use a "Triggered Capture" to acquire the Spectrogram. note: includes only measured frequencies, which are: 363, 366, 369, 372, 375, 378, 381, 384, 408, 417, 423Hz




12











2

CH 2 FrequencySimple Frequency Measurement (zero crossings)0 to 5000Hz1
13
2
CH 2 Total CurrentTotal current measured in the reed relay frequency range
0 to 5A
0 to 5000mA
50
10
14
2

CH 2 - channel 211

Total Current at 363Hz

0 to 5A
0 to 5000mA
50
10
15
2

CH 2 - channel 212

Total Current at 366Hz

0 to 5A
0 to 5000mA
50
10
16
2

CH 2 - channel 213

Total Current at 369Hz

0 to 5A
0 to 5000mA
50
10
17
2

CH 2 - channel 214

Total Current at 372Hz

0 to 5A
0 to 5000mA
50
10
18
2

CH 2 - channel 215

Total Current at 375Hz

0 to 5A
0 to 5000mA
50
10
19
2

CH 2 - channel 216

Total Current at 378Hz

0 to 5A
0 to 5000mA
50
10
20
2

CH 2 - channel 217

Total Current at 381Hz

0 to 5A
0 to 5000mA
50
10
21
2

CH 2 - channel 218

Total Current at 384Hz

0 to 5A
0 to 5000mA
50
10
22
2
CH 2 - spectrogram / gain

Capture waveform showing the magnitude spectrum of the input signal. Use a "Triggered Capture" to acquire the Spectrogram. note: includes only measured frequencies, which are: 363, 366, 369, 372, 375, 378, 381, 384, 408, 417, 423Hz





Aster

Slave ChannelVTI21 Input ChannelQuantityDescriptionTypical RangeUnitsSuggested AoC Threshold
1










1

Lock-on Frequency Ideal operating frequency track circuit1700 to 2600Hz1
2In-band CurrentRMS current in the operating band0-5000uA50
3Principle FrequencyLoudest frequency observed (actual operating frequency)1700 to 2600Hz1
4Total Currentbroad-and RMS current0-5000uA50
51700 Hz Band CurrentRMS current in the 1700 Hz band0-5000uA50
62000 Hz Band CurrentRMS current in the 1900 Hz band0-5000uA50
72300 Hz Band CurrentRMS current in the 2100 Hz band0-5000uA50
82600 Hz Band CurrentRMS current in the 2300 Hz band0-5000uA50
9Gain / FFTPre-amp Gain as AoC, Spectrogram is acquired as a triggered capture10HzNA
10











2

Lock-on Frequency Ideal operating frequency track circuit1700 to 2600Hz1
11In-band CurrentRMS current in the operating band0-5000uA50
12Principle FrequencyLoudest frequency observed (actual operating frequency)1700 to 2600Hz1
13Total Currentbroad-and RMS current0-5000uA50
141700 Hz Band CurrentRMS current in the 1700 Hz band0-5000uA50
152000 Hz Band CurrentRMS current in the 1900 Hz band0-5000uA50
162300 Hz Band CurrentRMS current in the 2100 Hz band0-5000uA50
172600 Hz Band CurrentRMS current in the 2300 Hz band0-5000uA50
118Gain / FFTPre-amp Gain as AoC, Spectrogram is acquired as a triggered capture10HzNA


VTI21-RFDM

note: only one input channel is supported.

Slave Channel

VTI21 Input Channel

Quantity

Description

Typical Range

Units

Suggested AoC

1










1

FrequencySimple Frequency Measurement (zero crossings)0-1000Hz50
2Total CurrentTotal current measured in the reed relay frequency range0-5AmA100
3FFTFFT for each monitored Channel
HzNA
4channel 4Energy at 803.25Hz0-5AmA100
5channel 16Energy at 702.5Hz0-5AmA100
6channel 17Energy at 697.5Hz0-5AmA100
7channel 19Energy at 687Hz0-5AmA100
8channel 20Energy at 682.5Hz0-5AmA100
9channel 26Energy at 611.75Hz0-5AmA100
10channel 27Energy at 607.75Hz0-5AmA100
11channel 36Energy at 505Hz0-5AmA100
12channel 38Energy at 493.5Hz0-5AmA100
13channel 39Energy at 488Hz0-5AmA100
14channel 47Energy at 419.75Hz0-5AmA100
15channel 48Energy at 410.25Hz0-5AmA100
16channel 83Energy at 446Hz0-5AmA100
17channel 84Energy at 533.75Hz0-5AmA100
18channel 92Energy at 842Hz0-5AmA100