The SA-SSI includes the same hardware as a basic SA380TX, that is 1- 10 digital inputs, RS485 and a GSM modem.

...

The purpose of an SA-SSI is to montor monitor Solid State Interlockings through utilisation of its front USB port.

...

Can be found here: SA380TX Hardware

Orderable Parts

NR Cat. No.

MPEC Part No.

Description


SA-SSI-GB

SA380TX unit generic base loaded with software specifically for the monitoring of SSI trackside data links.

Requires Park Signalling part no’s ST101, ST110 and ST112 (sold separately) to function.


SA-SSI-PS

SA380TX unit generic base loaded with software specifically for the monitoring of SSI trackside data links.

Includes 1 of each Park Signalling part no’s ST101, ST110 and ST112.


SA-SSI-PD

SA380TX unit generic base loaded with software specifically for the monitoring of SSI trackside data links.

Includes 2 of each Park Signalling part no’s ST101, ST110 and ST112.