Comment: Made a note about AOC threshold for tracks monitoring

...

  1. Setup analogue input channel: set channel name and input sensor
  2. Setup data acquisition type

GUI

Setting up analogue input channel

First of all you have to set an appropriate name and input sensor for the analogue channel.

...

Select the appropriate sensor and press the "OK" button to select it for the analogue channel.

Image RemovedImage Added If you are happy with the analogue channel settings, press Save: Image RemovedImage Added

The logger will notify you about the configuration changes:

...

The actual input value can be read on the graph. (Which is -5A now, since we don't have actual sensor connected to the analogue channel.)

Setting up analogue data acquisition

  then enter password and enter: 

Image Added

The next selector dialog shows which analogue channels are collecting acquire-on-change measurements:

Image Added 

select 701 WI channel: 

Image Added

Brings you to the acquire-on-change configuration dialog:

Image Added 

Most importants settings are the ON/OFF and the "Push to server" toggle buttons.

For a typical configuration, set the acquire-on-change threshold to 1% (lower than the default 5%), then toggle push to server and ON/OFF, then save the changes:

Image Added

Now the data collection method is set for the particular analogue channel. Let's see the collected data:

Go back to the main dialog by closing all the previous screens with the top-right "X" button.

Navigate to acquire-on-change historical data for analogue channel 701 WI:

Image Added Image Added Image Added Image Added

Image Added

Info
Notice that setting the acquire-on-change configuration will make the logger to acquire a first sample as a base value without any actual input change.

Web interface

Visiting the web interface we will focus on the Analogue Inputs part of the configuration.

Image Added

Let's set AN-A02 to a track circuit and enable acquire-on-change on it:

Set name:

Image Added

Set sensor:

Image Added

Set acquire-on-change:

Image Added

Send to logger:

Image Added WebCFG tool sends and retrieves the configuration again:Image Added

Check the output of the data acquisition:

Image Added Gets to: Image Added

Select today's date:

Image Added

Open acqchg folder:

Image Added

Open the new file for AB TR we just set up:

Image Added

The opened file must contain at least one sample as base acquisition.