Part No. | Variant Description | Quantity | Quantity Description | Value @ 4mA | Value @ 20mA | Units | Suggested AoC |
---|---|---|---|---|---|---|---|
VTI21-VT1 | AC Vane Relay Variant | Torque | Instantaneous Torque Exerted on the relay vane. | 0 | +25 | m.Nm | 0.2 m.Nm |
VTI21-HVI | HVI Receiver Variant | Average Current | Average HVI Pulsed Current seen by the VTI21 from input channel 1. | 0 | 600 | mA | 15 mA |
VTI21-TI21 | TI21 / EbiTrack 200 Variant | Average Current | Average of upper and lower sideband current from VTI21 input channel 1. | 0 | 1500 | mA | 5 mA |
VTI21-FS25 | FS2500 Receiver Variant | Center Current | Amplitude of the FS2500 center frequency current from VTI21 input channel 1. | 0 | 1500 | mA | 5 mA |
VTI21-FS26 | FS2600 Receiver Variant | Center Current | Amplitude of the FS2500 center frequency current from VTI21 input channel 1. | 0 | 1500 | mA | 5 mA |
VTI21-ACS | General Purpose AC sensing up to 20A 25A RMS | Current | RMS current from VTI21 input channel 1. | 0 | 2025 | A | 0.2 A |
VTI21-UM71 | UM71 Variant | Current | Current at selected center frequency from VTi21 input channel 1. | 0 | 5000 | µA | 100µA |
VTI21-ASTER | Aster Variant | Current | Current at selected center frequency from VTi21 input channel 1. | 0 | 5000 | µA | 100µA |
VTI21-REED | Reed Relay Variant | Current | Current measured across the Reed relay frequency range on input channel 1. | 0 | 5000 | mA | 100mA |
VTI21-RFDM | Reed Relay FDM variant | n/a | none |
...
Slave Channel | VTI21 Input Channel | Quantity | Description | Typical Range | Units | Suggested AoC |
---|---|---|---|---|---|---|
1 - ANA | 1 | HVI Current | RMS Current of the pulsed waveform | 0 to 1500 | mA | 15 mA |
2 - ANA | 1 | HVI Frequency | The frequency of pulses | 0 to 5 | Hz | 0.1 Hz |
3 - ANA | 1 | Noise Current | The RMS current observed between pulses. | 0 to 1500 | mA | 15 mA |
4 - ANA | 1 | Pulse Waveform | If this channel is requested as a capture, the VTi21 will return a high-resolution waveform of the last observed pulse | 0 to 1500 | mA | Triggered Capture |
1 - DIG | 1 | Pulse Conflict | Set TRUE if pulses are observed to be bleeding through from adjacent track sections | Digital | NA | On Change |
5 - ANA | 2 | HVI Current | RMS Current of the pulsed waveform | 0 to 1500 | mA | 15 mA |
6 - ANA | 2 | HVI Frequency | The frequency of pulses | 0 to 5 | Hz | 0.1 Hz |
7 - ANA | 2 | Noise Current | The RMS current observed between pulses. | 0 to 1500 | mA | 15 mA |
8 - ANA | 2 | Pulse Waveform | If this channel is requested as a capture, the VTi21 will return a high-resolution waveform of the last observed pulse | 0 to 1500 | mA | Triggered Capture |
2 - DIG | 2 | Pulse Conflict | Set TRUE if pulses are observed to be bleeding through from adjacent track sections | Digital | NA | On Change |
VTI21-ACS
...
Slave Channel | VTI21 Input Channel | Quantity | Description | Typical Range | Units | Suggested AoC | |||
---|---|---|---|---|---|---|---|---|---|
1 | 1 | CH 1 Current | RMS current observed on Channel 1 (output at 100 Hz, low pass filtered with cutoff of 9 Hz) | 0 to 250025 | mA | 5 mAA | 0.2 A | ||
22 | 1 | CH | 21 Average Current | Average RMS current observed on Channel 21, over one second period. | 0 to | 250025 | mA | 5 mAA | 0.2 A |
3 | NA2 | Derived CH 2 Current | RMS current derived for an unmonitored 3rd phase in a balanced three-phase system.observed on Channel 2 (output at 100 Hz, low pass filtered with cutoff of 9 Hz) | 0 to 250025 | mA | 5 mAA | 0.2 A | ||
4 | NA | CH1 Leads CH2 | Digital Output - TRUE if the waveform on CH1 is observed to lead that of CH2 | TRUE or FALSE | NA | NA | |||
5 | NA | CH1 Lags CH2 | Digital Output - TRUE if the waveform on CH1 is observed to lag that of CH2 | TRUE or FALSE | NA | NA |
VTI21-ACS-020
Slave Channel | VTI21 Input Channel | Quantity | Description | Typical Range | Units | Suggested AoC | |||||
---|---|---|---|---|---|---|---|---|---|---|---|
1 | 1 | CH 1 Current | RMS current observed on Channel 1 | 0 to 20 | A | 0.2 A | |||||
2 | 2 | CH 2 Current | RMS current observed on Channel 2 | 0 to 20 | A | 0.2 A | |||||
3 | NA | Derived Current | RMS current derived for an unmonitored 3rd phase in a balanced three-phase system. | 0 to 20 | A | 0.2 A | |||||
4 | NA | CH1 Leads CH2 | Digital Output - TRUE if the waveform on CH1 is observed to lead that of CH2 | TRUE or FALSE | NA | NA | |||||
5 | NA | CH1 Lags CH2 | Digital Output - TRUE if the waveform on CH1 is observed to lag that of CH2 | TRUE or FALSE | NA | NA2 | CH 2 Average Current | Average RMS current observed on Channel 2, over one second period. | 0 to 25 | A | 0.2 A |
VTI21-UM71
Slave Channel | VTI21 Input Channel | Quantity | Description | Typical Range | Units | Suggested AoC |
---|---|---|---|---|---|---|
1 | 1 | CH 1 Frequency | Channel 1 Frequency Selected | 1700 to 2600 | Hz | 1 |
2 | 1 | CH 1 Side Band Ratio | Ratio of lower to upper frequency (0%=all lower, 100%=all upper) | 0 to 100% | % | 5 |
3 | 1 | CH 1 Raw Frequency | Simple Frequency Measurement (zero crossings) | 1600 to 2700 | Hz | 100 |
4 | 1 | CH 1 Total Current | Total current in the UM71 band | 0 to 5mA | µA | 100 |
5 | 1 | CH 1 current 1700Hz | Current measured at 1700Hz | 0 to 5mA | µA | 100 |
6 | 1 | CH 1 current 2000Hz | Current measured at 2000Hz | 0 to 5mA | µA | 100 |
7 | 1 | CH 1 current 2300Hz | Current measured at 2300Hz | 0 to 5mA | µA | 100 |
8 | 1 | CH 1 current 2600Hz | Current measured at 2600Hz | 0 to 5mA | µA | 100 |
9 | 1 | CH 1 Spectrogram or Gain | Capture waveform showing the magnitude spectrum of the input signal. Use a "Triggered Capture" to acquire the Spectrogram. | 1 to 32 | 1 | |
10 | 2 | CH 2 Frequency | Channel 1 Frequency Selected | 1700 to 2600 | Hz | 1 |
11 | 2 | CH 2 Side Band Ratio | Ratio of lower to upper frequency (0%=all lower, 100%=all upper) | 0 to 100% | % | 5 |
12 | 2 | CH 2 Raw Frequency | Simple Frequency Measurement (zero crossings) | 1600 to 2700 | Hz | 100 |
13 | 2 | CH 2 Total Current | Total current in the UM71 band | 0 to 5mA | µA | 100 |
14 | 2 | CH 2 current 1700Hz | Current measured at 1700Hz | 0 to 5mA | µA | 100 |
15 | 2 | CH 2 current 2000Hz | Current measured at 2000Hz | 0 to 5mA | µA | 100 |
16 | 2 | CH 2 current 2300Hz | Current measured at 2300Hz | 0 to 5mA | µA | 100 |
17 | 2 | CH 2 current 2600Hz | Current measured at 2600Hz | 0 to 5mA | µA | 100 |
18 | 2 | CH 2 Spectrogram or Gain | Capture waveform showing the magnitude spectrum of the input signal. Use a "Triggered Capture" to acquire the Spectrogram. | 1 to 32 | 1 |
...