Data Acquisition Equipment ConnectionNotes
1RS485 "TX" data-stream A Connection
  • RS485 connections are device "outputs".
  • Traffic on the RS232 Transmit line is re-transmitted on this RS485 pair.
  • The output baud rate matches the input baud rate.
2RS485 "TX" data-stream B Connection
3RS485 "RX" data-stream A Connection
  • RS485 connections are device "outputs".
  • Traffic on the RS232 Receive line is re-transmitted on this RS485 pair.
  • The output baud rate matches the input baud rate.
4RS485 "RX" data-stream B Connection
5No Connection
6No Connection
7

-Power

  • Wide input power 9V to 30V DC.
  • Polarity protection provided.
8+ Power

...