  • An SA380TX is the master logger.
  • loggers are connected together using RS485.
  • Up to 7 devices can be slaved from a single SA380TX.
  • The TX can scan the bus on demand to auto-detect slaves.
  • Each slave device is identified by a unique identifier.

 

For correct operation it is important to arrange the slave units at consecutive places in the TX logger. If there is a gap in slave units or the first slave unit is missing, please remove all slaves units on the touch-screen (or simply revert the config to default), restart the TX master logger and start configuring the slave units starting slave #1.

...

Simplest way to make sure the configuration will build correctly is to revert to default configurationstart the configuration from scratch:

 go to advanced config:  Press "Reset config to default":  Press OK will restart the logger: 

...