Trackwork and point machines

 

Possible applications: 

  • Rail temperature
  • Rail vibration
  • Points load pin
  • Clamp lock power pack monitoring
  • Points position monitoring

...

Special care must be taken when attaching sensors to rails, pointwork, point machines or anything electrically connected to them.

Image Added

Sensor requirements:

  • Each sensor must have electrical isolation between the 4-20mA output and the trackwork to a minimum of 4M Ohms at 250V.
  • 250mA fuses must be provided in each leg of the current loop.
  • Only Network Rail approved points load pins may be used.
  • When monitoring the pressure in clamp lock power packs, only pressure sensors approved by the manufacturer of the power pack must be used.
  • Where sensors are attached to both rails, a risk assessment must be carried out to ensure that there is no risk of a track circuit being false fed

...

Other measurements

The 4-20mA analogue input card can be used with many other transducers, including temperature, pressure etc.

Parameter

Suggested 4-20mA device

Temperature

Phoenix Contact MINI MCR-SL-TC-UI(-NC)

Strain / force

Strainstall provide a wide range of sensors for measuring force in many different situations.

Flow

Omega FMG203-NPT

Wind speed

Vector Instruments (4-20mA special order)