Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

1 2 3
SyslogDescriptionExample
Thread stopped                  Software failure or possible overload.
Anchor
1thread=DiskLogger,state=8
Thread safety system restart    Software failure or possible overload.
Anchor
2 
Unexpected disk removal         Error: only for Internal 
Battery level low at startup    

Flat battery; battery is not charging. Let the logger charge the battery for a few hours.

If the error still shows, send the logger back to MPEC for battery replacement.

2.9V

Event receiver overflow         System is overloaded.
Anchor
3 
Could not delete folder         File system error? 
Could not create file           Important for SA380: must have external disk installed. 
Modem command failed            

Serial port error; modem error. It is not an error during modem baud-rate detection!

Try to restart communication on the logger.

missing echo
M Tx File processing failed     

Slow comms (file has been removed since), file system error.

Logger had no connection to the server long enough to fill the message queue in the meantime.

Check in the syslog if the GPRS communication was lost for a long time.

 

In case of system overload errors 123, it is a good idea to double-check the data collection settings. It is possible that the logger is collecting way too much data.

...