Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

SyslogDescriptionExample
Thread stopped                  software Software failure  or possible overload.thread=DiskLogger,state=8
Thread safety system restart    software Software failure or possible overload. 
Unexpected disk removal         Error: only for Internal 
Battery level low at startup    flat

Flat battery; battery is not charging

 

. Let the logger charge the battery for a few hours.

If the error still shows, send the logger back to MPEC for battery replacement.

2.9V

Event receiver overflow         system System is overloaded. 
Could not delete folder         File system error? 
Could not create file           Important for SA380: must have external 
Modem command failed            Serial port error; modem error. It is not an error during modem baud-rate detection! 
M Tx File processing failed     Slow comms (file has been removed since), file system error 

In case of system overload errors, it is a good idea to double-check the data collection settings. It is possible that the logger is collecting way too much data.

Acquire-on-change thresholds are the usual suspects. You may want to set the threshold higher.

GSM Modem

SA380TX

SyslogDescriptionExample
Modem power off                   
Modem power on                    
Modem command                   AT commands 
Modem command failed            check "Modem command" to find what triggered the error 
GSM signal strength at turn on    
Disconnecting RASdial           Ending GPRS connection 
RASdial disconnected            Important for SA380: must have external 
Creating RASdial entry          Have to add a number to Windows phone book to be able to call it with RasDial 
SIM registered to               Tells the network 
Could not reg. with GSM network International Mobile Subscriber Identity; International Mobile Station Equipment Identity 
GSM IMSI/IMEI                   International Mobile Subscriber Identity; International Mobile Station Equipment Identity 
Dialling RASdial entry          RasDial call; opening PPP connection; shows user,pass 
RASdial connected               RasDial succeded 
RASdial error                   err=Remote Access Error Codeerr=691
New RASserve timeout            RAS server started; timeout restarted 
DCD inactive (call cleared down)Modem data carrier line is down (connection lost) 
Disabling RAS server            RAS server stop 
DCD active (call connected)     TX2: Dialup has been called 
RING received                   Dialup during GPRS session 
GPRS started                    GPRS thread start 
GPRS ended                      GPRS thread end 
Modem fallback wait             Modem didn't manage to register to network, falling back for 1 hour 

...