- Single PCM 30 (bi directional CT) (analogue start & stop triggers) (Electrical Machines, e.g. M63, HW2000)
- A single PCM30 CT is used.
- Analogue triggers are start and stop data capture on the above channel.
- Single PCM 20 (Command relays - NWR, NWN) (digital start, analogue end) (Clamplocks, electrical or hydraulic)
- A Single CT collects data for motor current.
- Command relays start and stop data capture. (digital triggers)
- Single PCM 20 (Detection relays - NKR, RKR, digital start, digital end) (Clamplocks, electrical or hydraulic)
- A Single CT collects data for motor current.
- Detection relays are used to start and stop data capture. (digital triggers)
- Two PCM 20 - (current triggered) (electrical machines)
- Two CTs are used for data collection, one per direction (Note: see mimosa Id setting below)
- Each CT provides its own trigger for data collection (analogue triggers)
- Single PCM 20 - Valve CTs, CT on N-R and R-N valve (hydraulic machines)
- CTs are placed on Analogue triggers from Valve CT.
For a switch, there are generally two transitions which should be recorded, N-R and R-N. The SA380TX allows grouping of capture events
...