  • Single PCM 30 (bi directional CT) (analogue start & stop triggers) (Electrical Machines, e.g. M63, HW2000)
    • A single PCM30 CT is used.
    • Analogue triggers are start and stop data capture on the above channel.
  • Single PCM 20 (Command relays - NWR, NWN) (digital start, analogue end) (Clamplocks, electrical or hydraulic)
    • A Single CT collects data for motor current.
    • Command relays start and stop data capture. (digital triggers)
  • Single PCM 20 (Detection relays - NKR, RKR, digital start, digital end) (Clamplocks, electrical or hydraulic)
    • A Single CT collects data for motor current.
    • Detection relays are used to start and stop data capture.  (digital triggers)
  • Two PCM 20 - (current triggered, note: channel mapping) (electrical machines)
    • Two CTs are used for data collection (warning: see mimosa Id setting below)
    • Each CT provides its own trigger for data collection (analogue trigger)
  • Single PCM 20 - Valve CTs, CT on N-R and R-N valve (hydraulic machines)

...