The SA380TX-L is limited to a total of 12 captures, which and if both N-R and R-N swings are to be collected, this will cover 6 ends of points. A paired capture is used when direction information is to be passed to centrix, or the II.
Capture Channel
The logger will capture data from the specified channel, using the noise floor value to remove extraneous data from the beginning and end of a trace. The Swing indication is passed to the central server as appropriate.
Temperature Recording
The logger is capable of recording temperature data from any of its analogue channels. This is passed to the central server along with the capture data.
Trigger Configuration
The illustration shows a digital start trigger and an analogue end trigger.