Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
  • AzLM Axle Counter systems may be monitored by direct Ethernet or USB connection as shown below:

...

  • .

...

  • Ethernet connection is the most economical, but is not possible where the Ethernet connection is already in use. 1 x S-LX may monitor 2 x Axle Counter Evaluators. (ACE) over Ethernet

...

  • Where the Ethernet connection is use. Follow the guidance for connection over USB. 1 x S-LX may monitor 1 x Axle Counter Evaluators. (ACE) over USB.

  • In the USB Configuration, Additional ACE ACEs may be monitored through the provision of an Ethernet hub, allowed a single antenna to be used.

...

  • by utilising both serial ports on the Internet connected S-LX compute device, or via bridging the Wireless connection through multiple S-LX devices. Contact MPEC for more information.

...

  • No additional configuration files are required prior to installation.

Note
  • Connection of the S-LX system is via a monitoring port. The AzLM system may remain in service during installation.

  • Security Safety is assured by only connecting to 1 of duplicated or triplicated CPU devices found in each ACE. (2oo2 or 2oo3 safety system)When connected over USB, do not make the USB connection to the same CPU that is connected to the Interlocking.) (See SLX-TYP-AZLM-1)

  • Where Ethernet ports are already in use on all ACE CPUs, connection via USB is required, using a special “air-gapped” variant of the S-LX in order to control safety and reliability risks to a tolerable level. (See SLX-TYP-AZLM-2)

  • Appropriate cables shall be provided by the customer

...

  • for Ethernet connection

Sample Overlay Diagram

View file
nameSLX-TYP-AZLM.pdf

...