Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 7 Next »

The current state of the SA-SSI data logging unit, including information about the it's current connection status, events and battery can be found on the status page.

To navigate to this press the "Status" button on the home page:


This will display the following page:


The indicators on the right of the page, display the current state of each application function. Further information on the meaning of each of these can be found in the following table.

Application FunctionBlackRedAmberGreenAdditional Information
InternetN/ANot connectedN/AConnectedInternet : [connection information]
SSIUSB adapter not connectedNo connection/communication with Park ModuleIncorrect identOKDisplay name: SSI/[site name]/[channel in use]
PowerN/ARunning on battery/battery voltage lowRunning on batter/battery voltage okMains connectedDisplay name: Power (Mains/Charging/Battery)
OSN/ANot startedMiss configuredOK
CentrixN/ANot connectedNo traffic for more than 1 minuteOK/Connected
EventsUninitialisedInternal faultMiss configuredOK
NTPN/ANot connectedClock not setOK
WatchdogN/AAn application has failedN/AAll OK

Internet connection and IP address

Further information regarding the IP address of the SA-SSI can be viewed by pressing on the "Internet" button, as shown below:


Navigating to the IP Addresses page will display all the IP addresses associated with the data logger, as shown below:




  • No labels