VTi21 Sensor Tables
4-20mA Sensor Tables
Part No. | Variant Description | Quantity | Quantity Description | Value @ 4mA | Value @ 20mA | Units | Suggested AoC |
---|---|---|---|---|---|---|---|
VTI21-VT1 | AC Vane Relay Variant | Torque | Instantaneous Torque Exerted on the relay vane. | 0 | +25 | m.Nm | 0.2 m.Nm |
VTI21-HVI | HVI Receiver Variant | Average Current | Average HVI Pulsed Current seen by the VTI21 from input channel 1. | 0 | 600 | mA | 15 mA |
VTI21-TI21-TX | TI21 / EbiTrack 200 Variant (TX) | Average Current | Average of upper and lower sideband current from VTI21 input channel 1. | 0 | 5 | A | 0.05 A |
VTI21-TI21-TX | TI21 / EbiTrack 200 Variant (RX) | Average Current | Average of upper and lower sideband current from VTI21 input channel 1. | 0 | 200 | mA | 2 mA |
VTI21-FS25 | FS2500 Receiver Variant | Center Current | Amplitude of the FS2500 center frequency current from VTI21 input channel 1. | 0 | 1500 | mA | 5 mA |
VTI21-FS26 | FS2600 Receiver Variant | Center Current | Amplitude of the FS2500 center frequency current from VTI21 input channel 1. | 0 | 1500 | mA | 5 mA |
VTI21-ACS | General Purpose AC sensing up to 25A RMS | Current | RMS current from VTI21 input channel 1. | 0 | 25 | A | 0.2 A |
VTI21-UM71 | UM71 Variant | Current | Current at selected center frequency from VTi21 input channel 1. | 0 | 5000 | µA | 100µA |
VTI21-ASTER | Aster Variant | Current | Current at selected center frequency from VTi21 input channel 1. | 0 | 5000 | µA | 100µA |
VTI21-REED | Reed Relay Variant | Current | Current measured across the Reed relay frequency range on input channel 1. | 0 | 5000 | mA | 25mA |
VTI21-RFDM | Reed Relay FDM variant | n/a | none |
RS485 Sensor Tables
VTI21-VT1
Slave Channel | Quantity | Description | Typical Range | Units | Suggested AoC |
---|---|---|---|---|---|
1 | Torque | Instantaneous torque exerted on the relay vane | -25 to +25 | m.Nm | 0.2 m.Nm |
2 | Phase | Phase angle between local coil and control coil currents | 0 to 180 | Degrees | 2 degrees |
3 | Local Current | RMS current in the local coil | 0 to 500 | mA | 5 mA |
4 | Control Current | RMS current in the track coil | 0 to 1000 | mA | 5 mA |
5 | Chatter | Degree of chatter | 0 to 100 | % | 5 % |
VTI21-TI21 / VTI21-FS25 / VTI21-FS26
Slave Channel | VTI21 Input Channel | Quantity | Description | Typical Range | Units | Suggested AoC |
---|---|---|---|---|---|---|
1 | 1 | Center Frequency | The Center frequency, in hertz, of the track circuit. | 388.8 to 508.8 | Hz | 1 Hz |
2 | Center frequency Current | Total RMS current at the target center frequency | 0 to 1000 | mA | 5 mA | |
3 | Lower Side Band current | Total RMS current at the target lower side band frequency | 0 to 1000 | mA | 5 mA | |
4 | Upper Side Band current | Total RMS current at the target upper side band frequency | 0 to 1000 | mA | 5 mA | |
5 | In Band Current | Total RMS current seen by the transducer between 300 to 600 Hz | 0 to 1000 | mA | 5 mA | |
6 | Spectrogram or Gain | Capture waveform showing the magnitude spectrum of the input signal. Use a "Triggered Capture" to acquire the Spectrogram. When spectrum data is not being acquired, this channel shows the current amplifier gain setting | 4.8 to 1228.8 | Hz | NA | |
7 | Loudest Frequency | The strongest frequency, in hertz, observed in the incoming waveform. | 4.8 to 1228.8 | Hz | 1 Hz | |
8 | Total Current | Total RMS current seen by the transducer. | 0 to 1000 | mA | 5 mA | |
9 | 2 | Center Frequency | The Center frequency, in hertz, of the track circuit. | 388.8 to 508.8 | Hz | 1 Hz |
10 | Center frequency Current | Total RMS current at the target center frequency | 0 to 1000 | mA | 5 mA | |
11 | Lower Side Band current | Total RMS current at the target lower side band frequency | 0 to 1000 | mA | 5 mA | |
12 | Upper Side Band current | Total RMS current at the target upper side band frequency | 0 to 1000 | mA | 5 mA | |
13 | In Band Current | Total RMS current seen by the transducer between 300 to 600 Hz | 0 to 1000 | mA | 5 mA | |
14 | Spectrogram or Gain | Capture waveform showing the magnitude spectrum of the input signal. Use a "Triggered Capture" to acquire the Spectrogram. When spectrum data is not being acquired, this channel shows the current amplifier gain setting | 4.8 to 1228.8 | Hz | NA | |
15 | Loudest Frequency | The strongest frequency, in hertz, observed in the incoming waveform. | 4.8 to 1228.8 | Hz | 1 Hz | |
16 | Total Current | Total RMS current seen by the transducer. | 0 to 1000 | mA | 5 mA |
VTI21-HVI
Slave Channel | VTI21 Input Channel | Quantity | Description | Typical Range | Units | Suggested AoC |
---|---|---|---|---|---|---|
1 - ANA | 1 | HVI Frequency | The frequency of pulses | 0 to 5 | Hz | 0.1 Hz |
2 - ANA | HVI Current | RMS Current of the pulsed waveform | 0 to 1500 | mA | 5 mA | |
3 - ANA | Noise Current | The RMS current observed between pulses. | 0 to 1500 | mA | 5 mA | |
4 - DIG | Pulse Conflict | Set TRUE if pulses are observed to be bleeding through from adjacent track sections | Digital | N/A | On Change | |
5 - ANA | Rejection Rate | Proportion of pulses deemed not to be genuine HVI pulses | 0 to 100 | % | Don't push to server - for diagnostic use by Mpec only | |
6 - ANA | Rejection Reason | Bitfield encoding the reason a pulse was not accepted. | 8 bits | N/A | ||
7- ANA | Sensitivity | Threshold used to identify pulse events | 0 to 2621440 | N/A | ||
8 - ANA | Pulse Waveform | If this channel is requested as a capture, the VTi21 will return a high-resolution waveform of the last observed pulse | 0 to 1500 | mA | Triggered Capture | |
9 - ANA | 2 | HVI Frequency | The frequency of pulses | 0 to 5 | Hz | 0.1 Hz |
10 - ANA | HVI Current | RMS Current of the pulsed waveform | 0 to 1500 | mA | 5 mA | |
11 - ANA | Noise Current | The RMS current observed between pulses. | 0 to 1500 | mA | 5 mA | |
12 - DIG | Pulse Conflict | Set TRUE if pulses are observed to be bleeding through from adjacent track sections | Digital | N/A | On Change | |
13 - ANA | Rejection Rate | Proportion of pulses deemed not to be genuine HVI pulses | 0 to 100 | % | Don't push to server - for diagnostic use by Mpec only | |
14 - ANA | Rejection Reason | Bitfield encoding the reason a pulse was not accepted. | 8 bits | N/A | ||
15 - ANA | Sensitivity | Threshold used to identify pulse events | 0 to 2621440 | N/A | ||
16 - ANA | Pulse Waveform | If this channel is requested as a capture, the VTi21 will return a high-resolution waveform of the last observed pulse | 0 to 1500 | mA | Triggered Capture |
VTI21-ACS
Slave Channel | VTI21 Input Channel | Quantity | Description | Typical Range | Units | Suggested AoC |
---|---|---|---|---|---|---|
1 | 1 | CH 1 Current | RMS current observed on Channel 1 (output at 100 Hz, low pass filtered with cutoff of 9 Hz) | 0 to 25 | A | 0.2 A |
2 | CH 1 Average Current | Average RMS current observed on Channel 1, over one second period. | 0 to 25 | A | 0.2 A | |
3 | 2 | CH 2 Current | RMS current observed on Channel 2 (output at 100 Hz, low pass filtered with cutoff of 9 Hz) | 0 to 25 | A | 0.2 A |
4 | CH 2 Average Current | Average RMS current observed on Channel 2, over one second period. | 0 to 25 | A | 0.2 A |
VTI21-UM71
Slave Channel | VTI21 Input Channel | Quantity | Description | Typical Range | Units | Suggested AoC |
---|---|---|---|---|---|---|
1 | 1 | CH 1 Frequency | Channel 1 Frequency Selected | 1700 to 2600 | Hz | 1 |
2 | CH 1 Side Band Ratio | Ratio of lower to upper frequency (0%=all lower, 100%=all upper) | 0 to 100% | % | 5 | |
3 | CH 1 Raw Frequency | Simple Frequency Measurement (zero crossings) | 1600 to 2700 | Hz | 100 | |
4 | CH 1 Total Current | Total current in the UM71 band | 0 to 5mA | µA | 100 | |
5 | CH 1 current 1700Hz | Current measured at 1700Hz | 0 to 5mA | µA | 100 | |
6 | CH 1 current 2000Hz | Current measured at 2000Hz | 0 to 5mA | µA | 100 | |
7 | CH 1 current 2300Hz | Current measured at 2300Hz | 0 to 5mA | µA | 100 | |
8 | CH 1 current 2600Hz | Current measured at 2600Hz | 0 to 5mA | µA | 100 | |
9 | CH 1 Spectrogram or Gain | Capture waveform showing the magnitude spectrum of the input signal. Use a "Triggered Capture" to acquire the Spectrogram. | 1 to 32 | 1 | ||
10 | 2 | CH 2 Frequency | Channel 1 Frequency Selected | 1700 to 2600 | Hz | 1 |
11 | CH 2 Side Band Ratio | Ratio of lower to upper frequency (0%=all lower, 100%=all upper) | 0 to 100% | % | 5 | |
12 | CH 2 Raw Frequency | Simple Frequency Measurement (zero crossings) | 1600 to 2700 | Hz | 100 | |
13 | CH 2 Total Current | Total current in the UM71 band | 0 to 5mA | µA | 100 | |
14 | CH 2 current 1700Hz | Current measured at 1700Hz | 0 to 5mA | µA | 100 | |
15 | CH 2 current 2000Hz | Current measured at 2000Hz | 0 to 5mA | µA | 100 | |
16 | CH 2 current 2300Hz | Current measured at 2300Hz | 0 to 5mA | µA | 100 | |
17 | CH 2 current 2600Hz | Current measured at 2600Hz | 0 to 5mA | µA | 100 | |
18 | CH 2 Spectrogram or Gain | Capture waveform showing the magnitude spectrum of the input signal. Use a "Triggered Capture" to acquire the Spectrogram. | 1 to 32 | 1 |
VTI21-Reed
Slave Channel | VTI21 Input Channel | Quantity | Description | Typical Range | Units | Suggested AoC |
---|---|---|---|---|---|---|
1 | 1 | CH 1 Frequency | Simple Frequency Measurement (zero crossings) | 0 to 5000 | Hz | 1 |
2 | CH 1 Total Current | Total current measured in the reed relay frequency range | 0 to 5000 | mA | 10 | |
3 | CH 1 - channel 211 | Total Current at 363Hz | 0 to 5000 | mA | 10 | |
4 | CH 1 - channel 212 | Total Current at 366Hz | 0 to 5000 | mA | 10 | |
5 | CH 1 - channel 213 | Total Current at 369Hz | 0 to 5000 | mA | 10 | |
6 | CH 1 - channel 214 | Total Current at 372Hz | 0 to 5000 | mA | 10 | |
7 | CH 1 - channel 215 | Total Current at 375Hz | 0 to 5000 | mA | 10 | |
8 | CH 1 - channel 216 | Total Current at 378Hz | 0 to 5000 | mA | 10 | |
9 | CH 1 - channel 217 | Total Current at 381Hz | 0 to 5000 | mA | 10 | |
10 | CH 1 - channel 218 | Total Current at 384Hz | 0 to 5000 | mA | 10 | |
11 | CH 1 - spectrogram / gain | Capture waveform showing the magnitude spectrum of the input signal. Use a "Triggered Capture" to acquire the Spectrogram. note: includes only measured frequencies, which are: 363, 366, 369, 372, 375, 378, 381, 384, 408, 417, 423Hz | ||||
12 | 2 | CH 2 Frequency | Simple Frequency Measurement (zero crossings) | 0 to 5000 | Hz | 1 |
13 | CH 2 Total Current | Total current measured in the reed relay frequency range | 0 to 5000 | mA | 10 | |
14 | CH 2 - channel 211 | Total Current at 363Hz | 0 to 5000 | mA | 10 | |
15 | CH 2 - channel 212 | Total Current at 366Hz | 0 to 5000 | mA | 10 | |
16 | CH 2 - channel 213 | Total Current at 369Hz | 0 to 5000 | mA | 10 | |
17 | CH 2 - channel 214 | Total Current at 372Hz | 0 to 5000 | mA | 10 | |
18 | CH 2 - channel 215 | Total Current at 375Hz | 0 to 5000 | mA | 10 | |
19 | CH 2 - channel 216 | Total Current at 378Hz | 0 to 5000 | mA | 10 | |
20 | CH 2 - channel 217 | Total Current at 381Hz | 0 to 5000 | mA | 10 | |
21 | CH 2 - channel 218 | Total Current at 384Hz | 0 to 5000 | mA | 10 | |
22 | CH 2 - spectrogram / gain | Capture waveform showing the magnitude spectrum of the input signal. Use a "Triggered Capture" to acquire the Spectrogram. note: includes only measured frequencies, which are: 363, 366, 369, 372, 375, 378, 381, 384, 408, 417, 423Hz |
Aster
Slave Channel | VTI21 Input Channel | Quantity | Description | Typical Range | Units | Suggested AoC Threshold |
1 | 1 | Lock-on Frequency | Ideal operating frequency track circuit | 1700 to 2600 | Hz | 1 |
2 | In-band Current | RMS current in the operating band | 0-5000 | uA | 50 | |
3 | Principle Frequency | Loudest frequency observed (actual operating frequency) | 1700 to 2600 | Hz | 1 | |
4 | Total Current | broad-and RMS current | 0-5000 | uA | 50 | |
5 | 1700 Hz Band Current | RMS current in the 1700 Hz band | 0-5000 | uA | 50 | |
6 | 2000 Hz Band Current | RMS current in the 1900 Hz band | 0-5000 | uA | 50 | |
7 | 2300 Hz Band Current | RMS current in the 2100 Hz band | 0-5000 | uA | 50 | |
8 | 2600 Hz Band Current | RMS current in the 2300 Hz band | 0-5000 | uA | 50 | |
9 | Gain / FFT | Pre-amp Gain as AoC, Spectrogram is acquired as a triggered capture | 10 | Hz | NA | |
10 | 2 | Lock-on Frequency | Ideal operating frequency track circuit | 1700 to 2600 | Hz | 1 |
11 | In-band Current | RMS current in the operating band | 0-5000 | uA | 50 | |
12 | Principle Frequency | Loudest frequency observed (actual operating frequency) | 1700 to 2600 | Hz | 1 | |
13 | Total Current | broad-and RMS current | 0-5000 | uA | 50 | |
14 | 1700 Hz Band Current | RMS current in the 1700 Hz band | 0-5000 | uA | 50 | |
15 | 2000 Hz Band Current | RMS current in the 1900 Hz band | 0-5000 | uA | 50 | |
16 | 2300 Hz Band Current | RMS current in the 2100 Hz band | 0-5000 | uA | 50 | |
17 | 2600 Hz Band Current | RMS current in the 2300 Hz band | 0-5000 | uA | 50 | |
118 | Gain / FFT | Pre-amp Gain as AoC, Spectrogram is acquired as a triggered capture | 10 | Hz | NA |
VTI21-RFDM
note: only one input channel is supported.
Slave Channel | VTI21 Input Channel | Quantity | Description | Typical Range | Units | Suggested AoC |
---|---|---|---|---|---|---|
1 | 1 | Frequency | Simple Frequency Measurement (zero crossings) | 0-1000 | Hz | 50 |
2 | Total Current | Total current measured in the reed relay frequency range | 0-5A | mA | 100 | |
3 | FFT | FFT for each monitored Channel | Hz | NA | ||
4 | channel 4 | Energy at 803.25Hz | 0-5A | mA | 100 | |
5 | channel 16 | Energy at 702.5Hz | 0-5A | mA | 100 | |
6 | channel 17 | Energy at 697.5Hz | 0-5A | mA | 100 | |
7 | channel 19 | Energy at 687Hz | 0-5A | mA | 100 | |
8 | channel 20 | Energy at 682.5Hz | 0-5A | mA | 100 | |
9 | channel 26 | Energy at 611.75Hz | 0-5A | mA | 100 | |
10 | channel 27 | Energy at 607.75Hz | 0-5A | mA | 100 | |
11 | channel 36 | Energy at 505Hz | 0-5A | mA | 100 | |
12 | channel 38 | Energy at 493.5Hz | 0-5A | mA | 100 | |
13 | channel 39 | Energy at 488Hz | 0-5A | mA | 100 | |
14 | channel 47 | Energy at 419.75Hz | 0-5A | mA | 100 | |
15 | channel 48 | Energy at 410.25Hz | 0-5A | mA | 100 | |
16 | channel 83 | Energy at 446Hz | 0-5A | mA | 100 | |
17 | channel 84 | Energy at 533.75Hz | 0-5A | mA | 100 | |
18 | channel 92 | Energy at 842Hz | 0-5A | mA | 100 |