Summary
TODO
Assets
Hy-Drive Points - Motor Current Alarm
Previously the Hy-Drive points alarms required hydraulic pressure monitoring, the points alarm wizard has now been updated to support the training of a Points Alarm against the motor current capture channel/s.
The points alarm wizard will generate a points alarm on a hy-drive asset that does not have any pressure channels, but does have motor current channels.
In the case of 2 motor current channels the alarm generated will use thresholds that are the least restrictive based on the training data on the two motor current channels.
DC Track Circuit - Second Track Relay
DC Track Circuit Assets can now allows be configured with an additional track relay (TR2).
Track Circuit Assets with this additional relay will use the following logic chart for display on the playback map:
TR1 - DN | TR1 - UP | TR1 - UNKNOWN | TR1 - No Relay | |
---|---|---|---|---|
TR2 - DN | Occupied | Occupied | Occupied | Occupied |
TR2 - UP | Occupied | Unoccupied | Unoccupied | Unoccupied |
TR2 - UNKNOWN | Occupied | Unoccupied | UNKNOWN | UNKNOWN |
TR2 - No Relay | Occupied | Unoccupied | UNKNOWN | UNKNOWN |
Alarms
Logger Contact Alarm
TODO Rearming & firing per individual logger
Security
Mandatory MFA
TODO mention warning, explain reasoning?
Minor amendments and fixed issue
Fixed an issue where the Alarm Wizard would fail and not notify the user.
Logger status would sometimes fail to show for certain logger types.
Some reports were failing to delete.
Raw analogue and digital reports run against a single hour were failing to complete.
Asset playback page navigation by Tag improved to align better with track occupations.
Loggers channels list dates now display in the correct timezone.
Virtual logger log message list now updates live to show new messages.