Release Version

Centrix R107

Release Date (Staging)

Release Date (Production)

Summary

DC Track Circuit

Second Track Relay

The DC Track Circuit Asset type now allows for the setting of an additional Track Relay [TR2]. You can set the Channel for this relay by editing the Asset:

Track Circuit Assets with this additional relay will use the following logic chart for display on the playback map:

TR1 - DN

TR1 - UP

TR1 - UNKNOWN

TR1 - No Relay

TR2 - DN

Occupied

Occupied

Occupied

Occupied

TR2 - UP

Occupied

Unoccupied

Unoccupied

Unoccupied

TR2 - UNKNOWN

Occupied

Unoccupied

UNKNOWN

UNKNOWN

TR2 - No Relay

Occupied

Unoccupied

UNKNOWN

UNKNOWN

Minor amendments and fixed issues

  • Fixed an issue where the Alarm Wizard would fail and not notify the user.

  • Fixed an issue with logger status not being shown for specific logger types

  • Fixed an issue where you would be unable to delete reports

  • No labels