29-10-20 Release 1231
New Features
- Easy VTi21 slave setup - The TX will set sensible default acquire on change values for newly configured VTi21s. These values are based on those found in the VTi21 Sensor Tables at the time of writing.
- Syslog on Centrix -Â The TX now pushes syslog entries to Centrix. See the "syslog" tab in the logger's RDAQ part:
- Better slave firmware update visibility -Â Slave firmware update status us now shown on the home screen as well as the "about" screen.
- DHCP server control -Â The TX's DHCP server (which is used to allow direct ethernet connections from e.g. a PC to a logger) is now disabled unless there is an active cellular network connection and the device's ethernet connection is not configured as a DHCP client. This resolves an issue where a logger connected to a wired network could attempt to send DHCP allocations to other devices.
Bugfixes
- Fixed an issue where digitals could not be set to push using webconfig when part of the logger's configuration was missing.
- Fixed an issue where multiple VTi21 slaves running HVI track circuit monitoring firmware would periodically restart.