SA380TX-L Firmware Changes from revision 2678 to 2787

Due to obsolescence of the HL8 modem, Radar / II users will require newer firmware to use newer TX-L units with the new RC7620-1 4G modem. The new firmware will be backwards compatible with all previous hardware revisions.

Here is a summary of changes between 2678 (the previous II approved firmware) and 2787 (the release candidate to support the new modem):

  • Added support for RC7620-1 modem.

  • Captures configured with same start and end triggers are “paired” (sent together with same tick time) in Mimosa mode. This is particularly useful for monitoring of clamp lock points.

  • Improved reliability of historic data tool in the web interface / dPanel.

  • Relative (%-based) acquire on change can be configured on channels through the web interface.

  • Fixed sideband ratio channels on Ebitrack positions 1-7 not being sent in MIMOSA mode.

  • Fixed incorrectly calculated capture start times in Mimosa.

  • Fixed rare condition where analog channel power could be spuriously disabled by brownout detection.

  • Improvements to RailDAQ (Centrix) connection stability. Added option for automatic protocol selection when connected to Centrix.