Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Next »


Overview of the S-LX

The S-LX system comprises of 3 main components mounted on standard DIN rail.

Power supply

The system is supplied through a product-approved isolated BX110 (or domestic mains) to B24 power supply. A single power supply will power 2 x S-LX computing modules and 4 x HZS232 port sniffers inclusive.

Industrial Computer (The S-LX)

The "brains" of the system is an industrial computer running application specific software.

  • 2 x Serial Ports (RS232 or RS485)
  • 2 x Ethernet ports for data transmission, or local master / slave networks.
  • 1 x 4G Modem for onward data transmission

It receives data on it's two  serial ports, processes this data and  forwards the processed data to the Centrix platform

In master/slave installations, only one S-LX device requires a modem, other devices can be networked together.

High-Impedance Serial Port Sniffer (The HZS232)

  • The HZS232 "taps into" RS232 serial lines using an application specific cable set
  • The device presents a high-impedance to monitored serial lines, and a fail-safe design, meaning it will not adversely affect the operation of the monitored serial link.
  • The device also "isolates" the signal. It can be thought of a as a "data diode". It is not electrically possible for the S-LX computer to interfere with the data on the monitored serial link.

VHLC

How it is connected

What data is available

How the Data is Presented

HXP-3

How it is connected

What data is available

How the data is presented

  • No labels