Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 5 Next »

New Features

Firmware Upgrade via Centrix (Automatically)


Changes

Configuration File Format Change

  • The SA380 will now report the time-drift of the on-board clock to Centrix.
    • A future release of Centrix will allow monitoring of clock drift to aid data analysis
    • The next SA380 firmware release is to support time-broadcast messages from Centrix, allowing all devices that share the Centrix platform exhibit tightly synchronised clocks.

Bug Fixes

  • An issue that resulted in a failure to set the cellular APN of certain mobile operators has been resolved .

Jira

Description

Status

Version

Notes

SA-2317 - Enable Remote Firmware Upgrade from Centrix Master CLOSED

Logger connects to centrix over RailDAQ protocol which allows remote firmware upgrade from Centrix.Complete>=600
Hotfix for LondonderryAPN setting modem command has been fixed. Used to send '\n' terminated command which is unterminated. (AT+CGDCONT, AT+CFUN commands were affected.)Complete>=602

SA-2461 - Config Migration During Firmware Upgrade CLOSED

Default GPRS configuration becomes Centrix. The configuration is also upgraded to JSON. It's a one time update. Downgrading the logger will lose the config changes!

Configuration is exposed at http://logger/stw webpage. Instead of *.stw binary files there will be a config.json file.

In review

  • No labels