New Features
Firmware Upgrade via Centrix (Automatically)
Changes
Configuration File Format Change
- The SA380 will now report the time-drift of the on-board clock to Centrix.
- A future release of Centrix will allow monitoring of clock drift to aid data analysis
- The next SA380 firmware release is to support time-broadcast messages from Centrix, allowing all devices that share the Centrix platform exhibit tightly synchronised clocks.
Bug Fixes
- An issue that resulted in a failure to set the cellular APN of certain mobile operators has been resolved .
Jira | Description | Status | Version | Notes |
---|---|---|---|---|
SA-2317 - Enable Remote Firmware Upgrade from Centrix Master CLOSED | Logger connects to centrix over RailDAQ protocol which allows remote firmware upgrade from Centrix. | Complete | >=600 | |
Hotfix for Londonderry | APN setting modem command has been fixed. Used to send '\n' terminated command which is unterminated. (AT+CGDCONT, AT+CFUN commands were affected.) | Complete | >=602 | |
SA-2461 - Config Migration During Firmware Upgrade CLOSED | Default GPRS configuration becomes Centrix. The configuration is also upgraded to JSON. It's a one time update. Downgrading the logger will lose the config changes! Configuration is exposed at http://logger/stw webpage. Instead of *.stw binary files there will be a config.json file. | In review |