Not yet for distribution! This is a work in progress.
This applies to SA380 units from Mod. State 4 onwards, bearing serial numbers above 4000, manufactured from 2023.
For older versions, see https://utils.mpec.co.uk/downloads/sa380_ug.pdf
Copyright
Copyright MPEC Technology Ltd. 2023.
Versions
Version | Date | Amendments |
---|---|---|
0 | October 2022 | Started confluence page. Not for release |
1 | March 2023 | Work-in-progress, adding bulk content |
Overview
The SA380 & SA380C are data capture devices intended for railway signalling relays in interlockings and at level crossings. A single device can monitor up to 384 separate relays, safely, reliably and precisely. That data is not only recorded locally, but transmitted live to our Centrix back-office service for graphical replay. This enables faults and operational incidents to be investigated faster, in more detail, and with less time spent on-site.
The MS4 update to the SA380 provides enhanced software and connectivity, while remaining a drop-in replacement for most existing SA380 installations.
A typical installation comprises a single device, and up to eight break-out-boards, to which spare contacts on relays are wired. However, multiple devices can be networked together, enabling up to 3072 relays to be monitored with the same timing precision.
Physical description
SA380
Width | 427mm |
---|---|
Depth | 122mm |
Height | 195mm |
SA380C
Width | 330mm |
---|---|
Depth | 122mm |
Height | 195mm |
Long Breakout Board
Intended to be mounted vertically on Unistrut racking
Width | 60mm |
---|---|
Length | 630mm |
Input channels | 48 |
Compact Breakout Board
Intended to be mounted on BR930 style relay racks
Width | 230mm |
---|---|
Length | 130mm |
Input channels | 48 |
Specifications and Ratings
Ports
Power supply | 50W @ 110 / 230V AC (External isolation not required) |
---|---|
Isolated Digital Input Channels | 48 … 192 (SA380C) 240 … 384 (SA380) |
USB ports | 3 |
Ethernet ports | 1 |
Antenna port | 1 (SMA) |
Aux. DC Output | 1 (Optional) |
Performance
Event record precision | 10ms |
---|---|
Internal clock accuracy | +/- 10ms |
Event memory | 16 million events * |
Operational life | 10 years |
MTBF | 200 years |
Internal UPS backup | 4 … 8 hours, depending on load |
* Sufficient for five months at a major London terminus.
Communications
100Mbps Ethernet (with MDI-X)
4G cellular modem (Speed dependent on network operator)
User interfaces
The device can be controlled:
Using the built-in touchscreen
Using the MPEC Connect app (Bluetooth)
Using a laptop and the local web interface
Remotely using Centrix
Back-office services
Designed to connect to Centrix for:
Graphical event playback
Near-real-time monitoring
Customisable fault alarms
Push notifications
Remote configuration and firmware upgrade
Integration with data from other MPEC products
Certificates & Approvals
Product-Approved for use on Network Rail infrastructure, and rigorously tested for long-term reliability
Environmental
✅ | BS EN 50125-3:2003 | Railway applications - Environmental conditions for equipment - Part 3: Equipment for signalling and telecommunications |
✅ | BS EN 60068-2-1 | Cold Temperatures: -25°C for 16 hours |
✅ | BS EN 60068-2-2 | Dry Heat: +70°C for 16 hours |
✅ | BS EN 60068-2-30:2005, Db | Humidity: 95% @ 55°C for 24 hours |
✅ | BS EN 60068-2-14 | Thermal Shock: -25°C to +70°C in 30 seconds |
✅ | BS EN 60068-2-64:2008, Fh | Vibration: 5Hz … 2000Hz, 2.3m/s² RMS, 3-Axis |
Electromagnetic
✅ | BS EN 301 489-1 V2.2.3 (2019/11) | Electromagnetic compatibility and Radio spectrum Matters (ERM); Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 1 |
✅ | BS EN 55032: 2015 | Conducted RF Emissions |
✅ | BS EN 55032: 2015 | Radiated Emissions |
✅ | BS EN 61000-4-2:2009 | Electrostatic Discharge: 4kV direct contact |
✅ | BS EN 61000-4-3: 2006 A1 A2 | Radiated RF Immunity 80 MHz to 1GHz |
✅ | BS EN 61000-4-4:2012 | Fast Transient and Burst Immunity: 2kV Pk |
✅ | BS EN 61000-4-5:2014 A1 | Surge Immunity: 2kV line-to-earth |
✅ | BS EN 61000-4-6:2014 | Conducted RF Immunity: 150kHz … 80MHz |
✅ | BS EN 300-220 | Spurious Emissions (tx) |
✅ | BS EN 300-220 | ERP |
Options and accessories
SA380 and SA380C devices can be supplied with a number of fitting and accessories.
Standard accessories (supplied with all units):
Cellular antenna with 6m cable
Mains flex
External USB disk
Specified accessories (to requirements, at no extra cost):
Breakout boards (standard / compact)
SCSI cable for breakout boards (lengths up to 4m)
Mounting brackets (wall / unistrut)
Further accessories (at extra cost)
Antenna cables longer than 6m
Ethernet switch w/ PSU
Ethernet cables
SCSI cable for breakout board (longer than 4m)
Contact MPEC to discuss requirements for your installation.
Common tasks
Routine inspection
The SA380 is designed to be a low-maintenance system, and should not require replacement parts during its rated life.
The following should be periodically confirmed:
All cable connections to the device are secure
The “Status” indication on the display is Green
If mains power is disconnected from the device, it continues to operate for at least 15min
The device is kept dry and clean. Dust with a soft cloth if necessary.
Servicing, including replacing the internal battery, can be carried out by the manufacturer.
Removing USB disk for investigation
In the event of a serious incident, the investigating authority may require recorded data. This is stored on the external USB disk.
Touch the display to activate
Press “Eject USB disk”
Press “Yes”
Remove USB disk from the the bottom of the device
Installation
Competence
N.B. This guide is not a substitute for the purchasing organisation's rules, standards and policies, which must be adhered-to at all times.
Wiring must be installed to Signal Works Testing Handbook.
Testing is to be carried out by a signalling tester competent to Section 3B (I)
Commissioning is to be carried out by a competent Instrumentation Engineer.
Before any work takes place a risk assessment and method statement for the installation and commissioning of the datalogger must be approved by the infrastructure controller
Mechanical
Mounting
When ordering, specify mounting type required. This can be:
For 21mm Unistrut racking (Shown above)
For direct attachment to a wall
These brackets are secured to the back of the device using 6mm M4 machine screws. Use of longer screws may seriously damage the device.
Allow 100mm below the bottom of the device to avoid sharp bends in the cables connected
Breakout boards
Each breakout board can be connected to up to 48 relays. these are also available in two variants:
Full-length (Standard)
Compact (for mounting on BR930-style racking
Either type of breakout board is connected to the device with a SCSI cable. These cables are available in a range of lengths. Specify when ordering.
Full length breakout boards have space to label each terminal. MPEC can supply adhesive labels printed to requirements.
Antenna
Installations where the cellular radio is used to connect to the internet require an external antenna.
Exactly placement will depend on local circumstances, but we recommend:
Antennas should be high up, facing upwards.
Antennas should not be mounted inside or underneath structures
Special consideration may be required in remote or hilly areas
The antenna wire should be screwed onto the device to finger-tightness. Overtightening with tools will damage the device.
USB Memory Stick
This should be plugged into “USB1”
A faulty or absent USB disk will cause the Fault LED to light
Electrical
Power supply
Each device is supplied with an IEC C13 lead, to be connected to an AC power supply.
This can be either 110V or 230V nominal
An external isolation transformer is not required
The device contains internal overcurrent protection
The supply should be fused at 1A, but a higher-rated fuse or MCB may be used where 1A is not available
Where the supply is protected by an MCB, this should be of a B-curve type
A wire retaining loop is provided to secure the power inlet connector. Ensure this is positioned around the incoming flex.
Relay wiring
SA380 Breakout Boards are designed to be connected to a spare contact pair on each relay.
This may be a Back (Normally closed) or Front (Normally open) contact
No other devices may be present in the circuit from relay to breakout board
Special care must be taken with Geographical Interlockings, as each set may include many internal connections. In no circumstances may Breakout Board terminals be connected to live signalling circuits.
Auxiliary DC Output
If specified, the device can be supplied with an auxiliary DC output, intended for connection to an ethernet switch used in master-slave networks. Use only the cables provided.
Configuration
SA380s are supplied with standard software configuration which is suitable for most purposes:
Judicial logging is active by default
Cellular networking is enabled by default, with automatic fallback to ethernet (using DHCP)
Centrix connection is automatic.
All installations will require:
A configured site name
A set of relay-channel mappings
Both of these can be configured using the built-in touchscreen interface, or (optionally) can be pre-configured by MPEC.
If using ethernet to connect the logger to Centrix, consult the person responsible for your network.
Indicator LEDs
The Power LED indicates the presence of a power supply to the processor. This can be either from the external mains, or internal battery.
The Run LED blinks in a “heartbeat” pattern to show the device’s firmware is running.
The Disk LED lights when data is being written to the external USB disk.
The Server LED lights when a connection has been established to Centrix, or to a Master logger in a local network
The Internet LED lights when the logger has access to the internet
The Fault LED lights in the event of an internal device fault. Note that this will also be lit during device startup.
The MPEC Connect button flashes when Bluetooth connectivity is enabled, and lights solid when a connection has been made to a phone/tablet.
If the button is not lit, pressing it will enable Bluetooth.
Using the touchscreen
The SA380 has a built-in touchscreen display, which can be used to monitor and configure most functions of the device.
Throughout this guide, the route through the menu system from the Home screen is marked with a compass (🧭 ) icon.
To save energy, the display will turn off after a period of inactivity. touch any part of it to reactivate.
Home
The coloured “Status” dot in the top-right of the page indicates overall device health using a “traffic light” system.
Press the “Eject USB” button before removing the external USB disk. Failure to do so may cause data corruption.
Home → MPEC (Information)
Information
The Information page describes the product and current firmware.
Please quote Model, Serial number and Firmware when contacting customer support.
Home → Status
Status
The Status page indicates the status of the device’s software functionality. The specific set of entries may vary depending on configuration, but a typical set is shown here.
Each entry has a status dot, indicating its current performance.
Green: Good
Yellow: Degraded
Red: Fault
Black: Disabled
Other: Special state
Touch entries shown with a bevelled border to see more detail.
The SA380 Inputs entry describes the status of the onboard digital inputs. In master-slave systems, this becomes a selectable list of devices in the network.
Home → Status → Network
Network
This page shows both connections to the internet, and local LAN
Ping time should be under 30ms for wired connections, and under 300ms
Multiple IP addresses may be shown when a local master has a cellular internet connection.
Home → Status → Battery
Battery
The SA380 has an integrated UPS battery which will degrade over the course of several years. This should be checked periodically for satisfactory performance.
When fully charged, the internal battery voltage should be above 13.5V
The battery is considered fully discharged at 12.0V
A satisfactory battery voltage while the logger has external power does not indicate satisfactory capacity or performance
To test battery capacity:
Disconnect the external power supply
Observe that the logger remains functional for a sufficient period (e.g. 15min)
Reconnect mains power
Confirm that the battery is now indicated as “Charging”
Home → Status → Judicial Logs
Judicial Logs
The Judicial Logging system writes a standardised record of input events to an external USB memory device, for use in the event of an operational incident.
This page shows the status of those records, and will indicate if the external memory device is absent or unusable.
Home → Status → Centrix
Centrix
This page shows how the logger transmits data to other MPEC products. In most cases, this is our Centrix server, but the same system is used by Slave devices to communicate with a Master device.
The “Queued” figure shows the number of events waiting to be sent to the remote service. In normal operation, this number should be and remain small. A large or increasing number indicates a poor or misconfigured network connection.
Home → Status → Processes
Processes
The processes list shows the status of internal software functions.
Home → Live channels
Live channels
This shows a paged view of every channel currently being logged, including those from slave dataloggers, and system-internal metrics.
Each channel has a preview graph, showing value against time. Channels that have changed recently are shown green, others are shown in grey.
Press any channel name to see more detail.
Home → Live events
Live events
This shows a list of the most recent digital events on the logger, with the most recent at the bottom. The page is updated live, and can be useful when investigating the sequence of relay operation.
Note that changes on Anlaogue channels are not shown
Home → Event log
Event log
Not yet documented
Home → System log
System log
The system log shows a record of the device’s internal functions. Use this page to investigate misconfigured or malfunctioning dataloggers
Home → Configuration → Passcode → Configuration
Configuration
N.B. The factory default passcode is ‘12345’. We recommend changing this to discourage tampering.
Most functions of the SA380 can be configured using the touchscreen. Advanced users can also configure the device remotely through Centrix.
The main configuration page typically shows six entries:
Placename: This is the name that will appear on Centrix and in logs. Typically the name of the interlocking, signalbox or REB
Setup Inputs: This allows to to name and configure input channels, including on slave loggers
Setup Networking: How the logger connects to the internet
Centrix server: How data is sent over the network either to Centrix or to a local master logger
Setup passcode
Extra options, including loading/saving configuration and firmware using a USB memory stick
Home → Configuration → Passcode → Configuration → Setup Inputs
Setup Inputs
This page lists sources of data for the logger, each of which can be configured separately.
The top entry “SA380 Inputs” is for built-in digital channels
In a master-slave network, slave loggers will appear as additional entries
The “Autoconfigure” button will add entries for new slave loggers
Select an input device to configure its input channels
Home → Configuration → Passcode → Configuration → Setup Inputs → [Any]
Input device
An input device can be given a custom name. This is primary useful in master-slave networks
An input device can be assigned a prefix. This is used for new channels that do not appear in the configuration
Select “Configure” to set-up individual channels
Home → Configuration → Passcode → Inputs → [Any] → Configure
Input device channels
N.B. Naming large numbers of channels using the touchscreen can be a slow process! MPEC customer service can convert Excel spreadsheets to SA380 configuration free of charge.
Each entry on this page corresponds to a logged input channel
The left-hand column shows the original ID of each channel. (e.g. A03 is Input card ‘A', channel number '3’)
The centre column shows the name of the device being monitored. Typically the name of a relay.
The right-hand column shows whether the relay is monitored using a Front or Back contact
If 'F' is selected, the channel is “On” when the circuit is closed
If 'B' is selected, the channel is “On” when the circuit is open
Use the buttons in the bottom corners to see more channels
Home → Configuration → Passcode → Networking
Setup Networking
The Networking page allows you to control how the device connects to the internet, and to local ethernet slaves.
The top four items relate to cellular networking:
If you are using a cellular network, the modem must be “On”
APN, User and Pass will depend on your network provider
Loggers installed by Network Rail typically use APN “mobile.o2.com”, User “o2web”, and Pass “o2web”
Cellular connections always use an IP address provided by the network operator
Lower items relate to ethernet connections:
DHCP Client: If enabled, the device will automatically use network settings provided by another device on the same network, which could be a router, or another datalogger.
DHCP Server: If enabled, the device will provide network settings to other devices on the network.
IP Address: If DHCP Client is disabled, use this to set a static IP address. Use CIDR notation to indicate a subnet mask (e.g. ‘/24’)
Route: The IP address of your router
DNS: The IP address of your DNS server (Usually the same as Route, above)
Using the web interface or app
The SA380 has a web interface, which can be accessed either over ethernet, or using the MPEC Connect app
With the MPEC Connect app
This is the preferred method for use with iPhones & iPads
This doesn’t work as of Mar 2023
With a desktop computer
Not generally reccomended
This only works if either:
The SA380 is connected to a router
You set a static IP address on your laptop
Enter the IP address of the SA380 in the address bar of your web browser. (Using port 80, which is the default)