Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 11 Next »

Release Version

Centrix R107

Release Date (Staging)

Release Date (Production)

Summary

TODO

key summary type assignee status resolution sprint
Loading...
Refresh

DC Track Circuit

Second Track Relay

The DC Track Circuit Asset type now allows for the setting of an additional Track Relay [TR2]. You can set the Channel for this relay by editing the Asset:

Track Circuit Assets with this additional relay will use the following logic chart for display on the playback map:

TR1 - DN

TR1 - UP

TR1 - UNKNOWN

TR1 - No Relay

TR2 - DN

Occupied

Occupied

Occupied

Occupied

TR2 - UP

Occupied

Unoccupied

Unoccupied

Unoccupied

TR2 - UNKNOWN

Occupied

Unoccupied

UNKNOWN

UNKNOWN

TR2 - No Relay

Occupied

Unoccupied

UNKNOWN

UNKNOWN

Points Alarm Wizard

Hy-drive points alarm with no pressure channels

Added the ability to use the points alarm wizard to generate a points alarm on a hy-drive asset that does not have any pressure channels, but does have motor current channels. The generation of this alarm uses our standard points generation method, except for when there are 2 motor current channels on the asset.

In the case of 2 motor current channels the alarm generated will use thresholds that are the least restrictive based on the training data on the 2 motor current channels.

Minor amendments and fixed issues

  • Fixed an issue where the Alarm Wizard would fail and not notify the user.

  • Logger status would sometimes fail to show for certain logger types.

  • Some reports were failing to delete.

  • Asset playback page navigation by Tag improved to align better with track occupations.

  • Loggers channels list dates now display in the site’s timezone.

  • Virtual logger log message list now receives live messages.