Summary
DC Track Circuit
Second Track Relay
The DC Track Circuit Asset type now allows for the setting of an additional Track Relay [TR2]. You can set the Channel for this relay by editing the Asset:
Track Circuit Assets with this additional relay will use the following logic chart for display on the playback map:
TR1 - DN | TR1 - UP | TR1 - UNKNOWN | TR1 - No Relay | |
---|---|---|---|---|
TR2 - DN | Occupied | Occupied | Occupied | Occupied |
TR2 - UP | Occupied | Unoccupied | Unoccupied | Unoccupied |
TR2 - UNKNOWN | Occupied | Unoccupied | UNKNOWN | UNKNOWN |
TR2 - No Relay | Occupied | Unoccupied | UNKNOWN | UNKNOWN |
Points Alarm Wizard
Hy-drive points alarm with no pressure channels
Added the ability to use the points alarm wizard to generate a points alarm on a hy-drive asset that does not have any pressure channels, but does have motor current channels. The generation of this alarm uses our standard points generation method, except for when there are 2 motor current channels on the asset.
In the case of 2 motor current channels the alarm generated will use thresholds that are the least restrictive based on the training data on the 2 motor current channels.
Minor amendments and fixed issues
Fixed an issue where the Alarm Wizard would fail and not notify the user.
Fixed an issue with logger status not being shown for specific logger types
Fixed an issue where you would be unable to delete reports
The total number of assigned devices as well as the license limit is shown on the license manager page.
Updated the navigation by tag to use the end of rail event on the asset playback page.
Loggers channels list uses the site’s timezone.
Updated the character set to validate more data.