Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Next »

  • Westronic 1024 TDM systems may be monitored by intercepting the RS232 monitoring link between modem and CPU.

  • The Westronic 1024 TDM features duplicated data links for redundancy. Two S-LX system are required for complete monitoring

  • Each Westronic 1024 TDM sub-system connects to an individual S-LX system

  • The S-LX systems are networked together, requiring a single celluar antenna connection, modem and SIM.

Connection of the S-LX system is via a live data link.

The 1024 TDM will be briefly inoperable whilst RS232 connections are being made.

Incorrect termination of wiring may prevent system operation.

If in doubt, contact MPEC for technical support.

  • The customer must supply a list of TDM channel names to MPEC prior to shipment in order to pre-configure the device.

  • The MPEC technical team will liaise with the customer to obtain this information.

 Sample Overlay Diagram

  • No labels