- Set local IP address. (The slave units will be needed to be configured to connect to this IP address.)
Press Menu:
Press Configuration and enter passcode:
Press Set local IP:
Enter appropriate master IP address, subnet mask and default gateway. The default – and most usual – settings are:
IP address: 10.0.1.1
Subnet mask: 255.255.252.0
Default gateway: 10.0.0.138
Press Enter when finished.
- Enter each slave unit's serial number to tell the master unit what slave data to anticipate.
Go to configuration menu:
Press RailDAQ master button:
Enter the SA380 slave units' serial numbers, which are written onto the slave unit box or can be read on the touchscreen in the About box:
When upgrading previous version of master/slave configuration, Slave 1 SA380 unit's IP address looks like:
...
- 10.
...
- 0.
...
- 2.1, Slave 2 is
...
- 10.
...
- 0.
...
- 2.2 etc.
Slave IP addresses:
- Slave 1: 10.0.2.1
- Slave 2: 10.0.2.2
- Slave 3: 10.0.2.3
- Slave 4: 10.0.2.4
- Slave 5: 10.0.2.5
- Slave 6: 10.0.2.6
- Slave 7: 10.0.2.7
Once finished entering all belonging slave units, press Done. The logger will restart.
Setting up SA380 slave unit:
...