Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Current Transducers (VTI21-ASTER, VTI21-UM71)



ModelMagnelab SCT-0400-001-40K
Output11.25 V per Amp
Accuracy<10%
Bandwidth1kHz to 25kHz
Phase ErrorUnspecified

Current Transducers (VTI21-VT1, VTI21-TI21-RX, VTI21-FS25, VTI21-FS26, VTI21-REED, VTI21-RFDM)



ModelMagnelab SCT-0400-001-NCAP
Output333mV per Amp
Accuracy<1%
Bandwidth5Hz to 25kHz
Phase Error<2 Degrees (Compensated by VTI21)

 Current Transducers (VTI21-HVI, VTI21-TI21-TX-LP)



ModelMagnelab SCT-0400-005
Output66.6 mV per Amp
Accuracy<1%
Bandwidth5Hz to 25kHz
Phase Error<2 Degrees (Compensated by VTI21)

Current Transducers (VTI21-ACS)



ModelMagnelab SCT-0400-010
Output33.3mV per Amp
Accuracy<1%
Bandwidth5Hz to 25kHz
Phase Error<2 Degrees (Compensated by VTI21)

Current Transducers (VTI21-TI21-TX)



ModelMagnelab SCT-0400-025
Output13.3mV per Amp
Accuracy<1%
Bandwidth5Hz to 25kHz
Phase Error<2 Degrees (Compensated by VTI21)

VTI21-Electrical



Analogue Inputs
Bandwidth20kHz
Range+/-1.25V Differential Input
Resolution

from 74μV to 2.4mV

(Inputs feature programmable Gain)

Accuracy

1% - SCT-0400-001-NCAP, SCT-0400-010, SCT-0400-005, SCT-0400-025

10% - SCT-0400-001-40K

Analogue Output
Bandwidth500 Hz
Range0-20mA Current Loop Output
Resolution19.5μA
Accuracy<1%
Serial Output
Physical Layer

EIA RS485

Baud Rate

115,200 bps
Protocol LayerMPEC Raildaq
Power Supply
Voltage12V to 24V DC
Power Consumption

12V 4-20mA Mode: 0.7W

12V RS485 Mode: 0.5W

24V 4-20mA Mode: 1.1W

24V RS485 Mode: 0.8W

...