General Arrangement Drawings

...

Orderable Parts

...

MPEC Part Number

...

Description

...

SLX-VHLC-SS

...

S-LX Assembly for single module Vaughn Harmon Level Crossings. 1 x HZS, 1 x S-LX

...

SLX-VHLC-DS

...

S-LX Assembly for twin module Vaughn Harmon Level Crossings.  2 x HZS, 1 x S-LX

...

SLX-S2-SS

...

S-LX Assembly for S2 TDM systems. 1 x HZS, 1 x S-LX

...

SLX-1024-DD

...

S-LX Assembly for 1024 TDM systems. 2 x HZS, 2 x S-LX

...

SLX-HXP3-SS

...

S-LX Assembly for HXP-3 Track Circuit Systems. 1 x HZS, 1 x S-LX

...

SLX-TT-SS

...

S-LX Assembly for SSI Tech's Terminal system. 1 x HZS, 1 x S-LX

...

SLX-AZLM-SS

...

S-LX Assembly for AZLM Axle Counter Evaluator. 1 x HZS, 1 x S-LX

...

SLX-TD-XSS

...

S-LX Assembly for Train Describer / MCS. 1 x HZS, 1 x S-LX, 1 x RS422 Isolator

...

SLX-0-KIT

...

S-LX Accessory Kit containing

  • 2 x DIN Rail End Stops

  • 2 x S-LX RS485 Port Connectors

  • 1 x S-LX Power Input Connector

  • 3 x HZS RS485 / DC Power Output Connectors

  • 1 x HZS RS232 Input Connector

  • 1 x HZS AC Power Connector

  • 2 x RS485 Link Cables

  • 2 x DC Power Link Cables

...

SLX-0-SPLT

...

1 x DB9 Serial Splitter Cable

...

SLX-0-DB9-x

...

1 x RS232 Cable, DB9 to Bare Ends

x = Cable length in meters

...

SLX-0-DB25-x

...

1 x RS232 Cable, DB25 to Bare Ends

x = Cable length in meters

...

SLX-0-GB

...

Replacement S-LX Compute Module

...

SLX-0-HZS

...

S-LX System Specifications

 Electrical

 

Serial Input (Non-Intrusive)

1 x RS232 Full-Duplex 3-Wire Input - 57.6 kbps Max.

Multipurpose Serial Input (Intrusive)

2 x RS232/422/485 Software Selectable

921.6 kbps Max.

Ethernet

2 x 10/100 Mbps MDIX - RJ45

USB

1 x USB 2.0 Host - Type A Connector

Cellular

LTE (4G) Modem with 3G fall-back

Supply Voltage

85 V to 250 V AC

Power Consumption

5 W Typical, 10 W Max

Wire Gauge for Power Supply Inputs.

2.5 mm sq. Max.

Further detailed specifications for S-LX compute & HZS PSU/Isolation module can be found below.

General Arrangement Drawings

...

S-LX Module Specification

 Electrical

 

CPU

ARM7 Cortex A8 1 GHz

RAM

512 MB DDR3 DRAM

OS

Debian Industrial Linux

Ethernet

2 x 10/100 Mbps MDIX - RJ45

Serial

2 x RS232/422/485 Software Selectable

921.6 kbps Max.

USB*

1 x USB 2.0 Host - Type A Connector

Cellular

LTE (4G) Modem with 3G fall-back

SIM

Standard Mini SIM

Storage

8 GB eMMC onboard

1 GB Industrial SD Card

Input Voltage

12 V to 24 V DC

Power Consumption

5.4 W Max

Isolation

> 4 MΩ at 1,000 V DC

Indications

Power, Storage, Connectivity, USB, Run, Fault, Signal Strength

*USB Port not Where USB hubs are utilised, these hubs must also be Network Rail Type Approved for Monitoring Applications without appropriate isolating USB Hub.

Mechanical

Length

129 mm

Width

27 mm

Depth

101 mm

Weight

230 g

Mounting

DIN Rail

Environmental Ratings

 

IP Rating

2X

IK Rating

06

Temperature Range

-5 to +55 °C

Flammability

UL94-V0

Environmental

EN 50125-3

EMC

EN 50121-4

HZS Module Specification

 Electrical

 

Serial Input

1 x RS232 Full-Duplex 3-Wire Input

Serial Output

2 x RS485 Half-Duplex 2-Wire Output

Baud Rate

57,600 bps max.

Input Impedance

> 1 MΩ on both RS232 TX and RX Lines

Power Supply

85 V to 250 V AC

Power Consumption

0.6 W (HZS Module Only)

Output Voltage

12 V DC +/- 5%

Maximum Output Load

9 W

Isolation

> 4 MΩ at 1,000 V DC

Indications

Power, TX Active, RX Active

Mechanical

Length

129 mm

Width

27 mm

Depth

101 mm

Weight

370 g 230 g

Mounting

DIN Rail

Environmental Ratings

 

IP Rating

3X

IK Rating

06

Temperature Range

-5 to +55 °C

Flammability

UL94-V0

Environmental

EN 50125-3

EMC

EN 50121-4

Creepage & Clearance

EN 50124-1

Electrical Safety

EN 61010-1

Network Rail Data Logging

NR/L2/SIG/30036

Orderable Parts

Part No:

Description

Photo

SLX-VHLC-SS

S-LX Assembly for single module Vaughn Harmon Level
Crossings.

1 x HZS, 1 x SLX, DIN Mount

Image Added

SLX-VHLC-DS

S-LX Assembly for twin module Vaughn Harmon Level
Crossings.

2 x HZS, 1 x SLX, DIN Mount

Image Added

SLX-TT-SS

S-LX Assembly for SSI Tech's Terminal system.

1 x HZS, 1 x SLX, DIN Mount

Image Added

SLX-SEAR-SS

S-LX Assembly for SEAR II Level Crossing

1 x HZS, 1 x SLX, DIN Mount

Image Added

SLX-SDL-SS

S-LX Assembly for SSI Data Links. Park Signalling Equipment Not Included.

1 x HZS, 1 x SLX, DIN Mount

Image Added

SLX-S2-SS

S-LX Assembly for S2 TDM systems.

1 x HZS, 1 x SLX, DIN Mount

Image Added

SLX-MCS-XSS

S-LX Assembly for MCS system.

1 x RS422 Isolator, 1 x HZS, 1 x SLX, DIN Mount

Image Added

SLX-HXP3-SS

S-LX Assembly for HXP-3 Track Circuit Systems.

1 x HZS, 1 x SLX, DIN Mount

Image Added

SLX-FUES-SS

S-LX Assembly for FUES Hot Axle Box Detector

1 x HZS, 1 x SLX, DIN Mount

Image Added

SLX-FLEX-0S

S-LX Assembly for Flex Life Level Crossing.

1 x SLX, DIN Mount

Image Added

SLX-AZLM-SS

S-LX Assembly for AzLM Axle Counter ACE with Parallel Card Interface. See application notes.

1 x HZS, 1 x SLX, 19” Rack Mount

Image Added

SLX-AZLM-SD

Air-Gapped S-LX Assembly for AzLM Axle Counter ACE with Serial Card Interface. See application notes.

1 x HZS, 2 x SLX, 19” Rack Mount

Image Added

SLX-1024-DD

S-LX Assembly for 1024 TDM systems.

2 x HZS, 2 x SLX, DIN Mount

Image Added

Spares & Accessories

Part No:

Description

Photo

MIS-WHP-06

2/3/4G Hi-Gain Mag-Mount Antenna with 6m Cable

Image Added

MIS-WHP-10

2/3/4G Hi-Gain Mag-Mount Antenna with 10m Cable

Image Added

MIS-WHP-15

2/3/4G Hi-Gain Mag-Mount Antenna with 15m Cable

Image Added

MIS-BRK-RACK

19” Rack, 1U Mounting Tray, fits S-LX , suitable for other applications

Image Added

MIS-BRK-DIN

Stainless Steel BR930 Size DIN Rail Bracket, fits S-LX, suitable for other applications

Image Added

SLX-0-DB9-X

DB-9 RS232 Cable - 'X' = Length in metres

Image Added

SLX-0-DB25-X

DB-25 RS232 Cable - 'X' = Length in metres

Image Added

SLX-0-SPLIT

DB-9 Three-Way Splitter Cable

Image Added

SLX-0-GB

Replacement S-LX compute module

Image Added

SLX-0-HZS

Replacement HZS PSU / Port Isolators

Image Added

SLX-0-KIT

Replacement plug-coupler kit. Contains all plug couplers

Image Added