Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Technical specifications

 

 

General

...

Digital inputs per unit

4, 12 or 20

Analogue inputs per unit

2, 6 or 10

Fixings

To fit standard BR930 relay rack

Size

135 x 57 x 175mm - 1 relay position

Processor

80MHz dual

RAM

256K

Internal flash storage

2GB

General

 

Digital inputs per unit

4, 12 or 20

Analogue inputs per unit

2, 6 or 10

Fixings

To fit standard BR930 relay rack

Size

135 x 57 x 175mm - 1 relay position

Processor

80MHz dual

RAM

256K

Internal flash storage

2GB

 

 

 

 

 

 

1GB


Communication ports

Ethernet10baseT

Internal modem

4G LTE with 3G and 2G fallback

RS485

 115,200 bps max.

Protocols

PPP, TCP/IP, HTTP,  FTP,  MIMOSA, RailDAQ


Digital input ports

Type

Volt-free relay contacts
Isolation Barrier10MOhm at 1,000V DC min
Max differential DC voltage55V


Analogue input ports

Range4-20mA
Resolution10 bit
Sampling rate1000 Hz Max.
Isolation Barrier10MOhm at 1,000V DC min


Power supply ports - AC unit

Power supply

90-264Vac
Isolation Barrier10MOhm at 1,000V DC min
Power consumption no inputs3W
Power consumption absolute max40W (0.36A at 110V)
Electrical Safety (< 130 V AC)OV CAT III, PD 2
Electrical Safety (> 130 V AC)OV CAT III, PD 1


Power supply ports - DC unit

Power supply

9-18Vdc
Isolation Barrier10MOhm at 1,000V DC min
Power consumption no inputs3W
Power consumption absolute max40W (3.34A at 12V)


...

MIMOSA parameter offsets

Main Offsets

OffsetTypeMeaning
0-Base ID of logger
1

DABLOBData

SNTP time server domain name
2DABLOBDataFTP Server domain name
3DABLOBDataPrimary server domain name
4DABLOBDataSecondary server domain name

5

DABoolHeartbeat

6

DAInt

Heartbeat interval
7DABLOBData

FTP download request

8DABLOBDataFTP download report

9

DABLOBData

Firmware update request

10-31

-

Reserved

32

DABool

System reset

34DABoolRestart comms
64-75

DAWaveform

Triggered captures 1-12 recorded waveforms

128-147DABool

Digital inputs

576-585DADataSeq

Analogue inputs 1-10 using Acquire-on-Change

1024-1035

DAInt

Triggered captures 1-12 direction indicators

2048-2303

Various

EbiTrack 0

2304-2559

Various

EbiTrack 1
2560-2815

Various

EbiTrack 2

2816-3071VariousEbiTrack 3
3072-3327

Various

EbiTrack 4

3328-3583

VariousEbiTrack 5

3584-3839

Various

EbiTrack 6
3840-4095

Various

EbiTrack 7


EbiTrack Offsets

OffsetTypeMeaning

+0

DABoolConnection Status
+1

DADataSeq

Temperature (TEMP)

+2DADataSeqSupply Voltage (VPSU)

+15

DABOLBData

Serial No. (SERN)
+16

DAInt

Mod State (MODS)

+17

DABOLBDataFrequency Code (FREQ)
+19DABOLBDataKey No. (KYSN)

+20

DAInt

Error Code
+24DABOLBDataAutoset Key No. (ASSN)
+26DAIntCurrent Threshold (ITHR)
+27

DADataSeq

Relay Output Voltage (VOUT)
+28DADataSeq

Relay Output Current (IOUT)

+29

DADataSeqUpper Sideband Current (IUSB)
+30

DADataSeq

Lower Sideband Current (ILSB)

+31

DADataSeq

Average Sideband Current (IAVE)

+32DABoolUnit Error (Bit 6 of STAT)
+253DADataSeqIUSB/ILSB (SBRT, Side band Ratio)