Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Technical specifications

 

 

...

General

Digital inputs per unit

4, 12 or 20

Analogue inputs per unit

2, 6 or 10

Fixings

...

To fit standard BR930 relay rack

Size

...

135 x 57 x 175mm - 1 relay position

Processor

80MHz dual

...

RAM

256K

Internal flash storage

...

 

Technical specifications

 

 

Column
width50%

General   

Digital inputs per unit 4, 12

Analogue inputs per unit 2, 6 or

Fixings  To fit

Size  135 x

Processor 80MHz

RAM  256K

Internal flash storage 2GB

 

...

1GB


Communication ports

Ethernet10baseT

Internal modem

4G LTE with 3G and 2G fallback

RS485

 115,200 bps max.

Protocols

PPP, TCP/IP, HTTP,  FTP,  MIMOSA, RailDAQ


Digital input ports

Type

Volt-free relay contacts
Isolation Barrier10MOhm at 1,000V DC min
Max differential DC voltage55V


Analogue input ports

Range4-20mA
Resolution10 bit
Sampling rate1000 Hz Max.
Isolation Barrier10MOhm at 1,000V DC min


Power supply ports - AC unit

Power supply

90-264Vac
Isolation Barrier10MOhm at 1,000V DC min
Power consumption no inputs3W
Power consumption absolute max40W (0.36A at 110V)
Electrical Safety (< 130 V AC)OV CAT III, PD 2
Electrical Safety (> 130 V AC)OV CAT III, PD 1


Power supply ports - DC unit

Power supply

9-18Vdc
Isolation Barrier10MOhm at 1,000V DC min
Power consumption no inputs3W
Power consumption absolute max40W (3.34A at 12V)


...

MIMOSA parameter offsets

Main Offsets

OffsetTypeMeaning
0-Base ID of logger
1

DABLOBData

SNTP time server domain name
2DABLOBDataFTP Server domain name
3DABLOBDataPrimary server domain name
4DABLOBDataSecondary server domain name

5

DABoolHeartbeat

6

DAInt

Heartbeat interval
7DABLOBData

FTP download request

8DABLOBDataFTP download report

9

DABLOBData

Firmware update request

10-31

-

Reserved

32

DABool

System reset

34DABoolRestart comms
64-75

DAWaveform

Triggered captures 1-12 recorded waveforms

128-147DABool

Digital inputs

576-585DADataSeq

Analogue inputs 1-10 using Acquire-on-Change

1024-1035

DAInt

Triggered captures 1-12 direction indicators

2048-2303

Various

EbiTrack 0

2304-2559

Various

EbiTrack 1
2560-2815

Various

EbiTrack 2

2816-3071VariousEbiTrack 3
3072-3327

Various

EbiTrack 4

3328-3583

VariousEbiTrack 5

3584-3839

Various

EbiTrack 6
3840-4095

Various

EbiTrack 7


EbiTrack Offsets

OffsetTypeMeaning

+0

DABoolConnection Status
+1

DADataSeq

Temperature (TEMP)

+2DADataSeqSupply Voltage (VPSU)

+15

DABOLBData

Serial No. (SERN)
+16

DAInt

Mod State (MODS)

+17

DABOLBDataFrequency Code (FREQ)
+19DABOLBDataKey No. (KYSN)

+20

DAInt

Error Code
+24DABOLBDataAutoset Key No. (ASSN)
+26DAIntCurrent Threshold (ITHR)
+27

DADataSeq

Relay Output Voltage (VOUT)
+28DADataSeq

Relay Output Current (IOUT)

+29

DADataSeqUpper Sideband Current (IUSB)
+30

DADataSeq

Lower Sideband Current (ILSB)

+31

DADataSeq

Average Sideband Current (IAVE)

+32DABoolUnit Error (Bit 6 of STAT)
+253DADataSeqIUSB/ILSB (SBRT, Side band Ratio)