Westronic 1024 TDM systems may be monitored by intercepting the RS232 monitoring link between modem and CPU.
The Westronic 1024 TDM features duplicated data links for redundancy. Two S-LX system are required for complete monitoring
Each Westronic 1024 TDM sub-system connects to an individual S-LX system
The S-LX systems are networked together, requiring a single celluar antenna connection, modem and SIM.
Drawio | ||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Note |
---|
Connection of the S-LX system is via a live data link. The 1024 TDM will be briefly inoperable whilst RS232 connections are being made. Incorrect termination of wiring may prevent system operation. If in doubt, contact MPEC for technical support. |
Note |
---|
The gender of the DB-9 connecting pins and locking nuts/screws my differ depending on the TDM1024 model. Please supply a photo of the TDM1024 input port with no cable attached to MPEC when ordering to assure the correct cable sets are received. |
Info |
---|
|
Sample Overlay Diagram
View file | ||
---|---|---|
|