Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


Jira

Description

Status

Version

Notes

Image AddedSA-2317 - Enable Remote Firmware Upgrade from Centrix Master CLOSED

Logger connects to centrix over RailDAQ protocol which allows remote firmware upgrade from Centrix.Complete>=600
Hotfix for LondonderryAPN setting modem command has been fixed. Used to send '\n' terminated command which is unterminated. (AT+CGDCONT, AT+CFUN commands were affected.)Complete>=602

Image AddedSA-2461 - Config Migration During Firmware Upgrade CLOSED

Default GPRS configuration becomes Centrix. The configuration is also upgraded to JSON. It's a one time update. Downgrading the logger will lose the config changes!

Configuration is exposed at http://logger/stw webpage. Instead of *.stw binary files there will be a config.json file.

In review