Firmware Status |
|
---|
Overview of Changes
Variant | New Version | Changed |
---|---|---|
Aster | 80 | Yes |
FS2600 | 80 | Yes |
Reed Relay | 80 | Yes |
UM71 | 80 | Yes |
VT1 | 80 | Yes |
New Features
...
VT1 Vane Relay
The 4-20 mA analogue output re-scaled:
Output Current | Old Torque | New Torque |
---|---|---|
4 mA | -25 | 0 |
20 mA | +25 | +25 |
This was to give a better signal-to-noise ratio on the 4-20mA output. A vane relay must never generate negative torque. To do so would imply a very short-time transient event, incorrect installation of the VTi21 or catastrophic failure of the VT1 track circuit.
...
This means that VTi21 firmware versions may increase evenĀ even there is no change. The release notes will continue to indicate which VTi21 variants have changed in each release.
Bug Fixes
...
All variants
- RS485 bugfix: Transmit data buffer could overflow causing data corruption.
- RS485 bugfix: Transmit data could be incorrectly encoded causing data corruption.
- AoC bufix: Large AoC settings could be mis-interpreted and end up manifesting as a very small AoC setting on the VTi21.
...