SA380TX Configuration
...
The unit can be upgraded to this version of firmware if required using dUpgrade, following the instructions found in the dUpgrade User Guide.
Alternatively the firmware can also be upgraded using USB, following the SA380TX Firmware Upgrade using USB instructions.
...
The Aster VTI21 sensor can output the following quantities when monitoring Aster receivers.
Quantity | Units | Change Threshold | 4-20 mA | RS485 |
CH1_Aster | Hz | 1 |
| |
CH1_ICent | uA | 10 | ||
CH1_Freq | Hz | 1 | ||
CH1_ITot | uA | 10 | ||
CH1_1700 | uA | 10 | ||
CH1_2000 | uA | 10 | ||
CH1_2300 | uA | 10 | ||
CH1_2600 | uA | 10 | ||
CH1_FFT | Not normally acquired | |||
CH2_Aster | Hz | 1 | ||
CH2_ICent | uA | 10 | ||
CH2_Freq | Hz | 1 | ||
CH2_ITot | uA | 10 | ||
CH2_1700 | uA | 10 | ||
CH2_2000 | uA | 10 | ||
CH2_2300 | uA | 10 | ||
CH2_2600 | uA | 10 | ||
CH2_FFT | Not normally acquired |