Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Page Properties

Release Version

Centrix R107

Release Date (Staging)

TBD

Release Date (Production)

TBD

Summary

Table of Contents
minLevel1
maxLevel7
excludeSummary.*

...

Jira Legacy
serverSystem JIRA
columnskey,summary,type,assignee,status,resolution,sprint
maximumIssues50
jqlQueryproject = 'Centrix' AND fixVersion = "Centrix R107" AND Sprint IN ("Iteration 206", "Iteration 207") ORDER BY key ASC
serverId588b3277-2d3f-3f93-8553-28aac6672408

Assets

Hy-Drive Points - Motor Current Alarm

Previously the Hy-Drive points alarms required hydraulic pressure monitoring, the points alarm wizard has now been updated to support the training of a Points Alarm against the motor current capture channel/s.
The points alarm wizard will generate a points alarm on a hy-drive asset that does not have any pressure channels, but does have motor current channels.

In the case of 2 motor current channels the alarm generated will use thresholds that are the least restrictive based on the training data on the two motor current channels.

DC Track Circuit

...

- Second Track Relay

The DC Track Circuit Asset type Assets can now allows for the setting of an additional Track Relay [TR2]. You can set the Channel for this relay by editing the Asset:be configured with an additional track relay (TR2).

...

Track Circuit Assets with this additional relay will use the following logic chart for display on the playback map:

TR1 - DN

TR1 - UP

TR1 - UNKNOWN

TR1 - No Relay

TR2 - DN

Occupied

Occupied

Occupied

Occupied

TR2 - UP

Occupied

Unoccupied

Unoccupied

Unoccupied

TR2 - UNKNOWN

Occupied

Unoccupied

UNKNOWN

UNKNOWN

TR2 - No Relay

Occupied

Unoccupied

UNKNOWN

UNKNOWN

Alarms

Points Alarm Wizard

Hy-drive points alarm with no pressure channels

Added the ability to use the points alarm wizard to generate a points alarm on a hy-drive asset that does not have any pressure channels, but does have motor current channels. The generation of this alarm uses our standard points generation method, except for when there are 2 motor current channels on the asset.

...

Logger Contact Alarm

TODO Rearming & firing per individual logger

Security

Mandatory MFA

TODO mention warning, explain reasoning?

Minor amendments and fixed

...

issue

  • Fixed an issue where the Alarm Wizard would fail and not notify the user.

  • Logger status would sometimes fail to show for certain logger types.

  • Some reports were failing to delete.

  • Raw analogue and digital reports run against a single hour were failing to complete.

  • Asset playback page navigation by Tag improved to align better with track occupations.

  • Loggers channels list dates now display in the site’s correct timezone.

  • Virtual logger log message list now receives updates live to show new messages.